BK PRECISION 2120 CALIBRATION and BK PRECISION 2120 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 2120 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   BK PRECISION 2120   Description / Specification:    
BK PRECISION 2120 2 Ch 20 MHz Analog Oscilloscope

The BK Precision 2120 20 MHZ Analog, 2 Channel oscilloscope offers dual or single trace operation 1 mV/div sensitivity. It is an excellent oscilloscope for production test, depot level repair and educational purposes. Specifications. Vertical Sensitivity: 5 mV/div to 5 V/div, 1 mV/div to 1 V/div (PULL X5). Attenuator: 10 steps in 1-2-5 sequence, Vernier control provides full adjustment between steps. Accuracy: ±3%, ±5% at PULL X5. Input Resistance: 1 M-ohm ±2%. Input Capacitance: 25 pF ±10 pF. Frequency Response 5 mV to 5 V/div: DC to 20 MHz (-3dB). Frequency Response 1 mV to 1 V/div PULL X5: DC to 10 MHz (-3dB). Rise Time: 17.5 ns, 35 ns at PULL X5. Maximum Input Voltage: 400 V (DC + AC peak). Horizontal X-Y Mode: switch selectable using X-Y switch. Sensitivity: Same as vertical channel 2. Frequency Response: DC to 2 MHz typical (-3 dB). X-Y Phase Difference: Approximately 3° at 50 kHz. Sweep Speed: 0.5 µs/div to 0.5 s/div in 1-2-5 sequence, 19 steps Vernier control provides fully adjustable sweep time between steps. Accuracy: ±3%. Triggering Modes: AUTO (free run) or NORM. Trigger Source: CH 1, CH 2, ALT, EXT, LINE.



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 2120. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your BK PRECISION 2120 CALIBRATION and/or BK PRECISION 2120 2 Ch 20 MHz Analog Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: