BK PRECISION 2125A CALIBRATION and BK PRECISION 2125A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 2125A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   BK PRECISION 2125A   Description / Specification:   Spec Sheet 
BK PRECISION 2125A 2 Ch 30 MHz Delay Trace Analog Oscilloscope

The B+K Precision 2125A is a dual trace 30 MHz oscilloscope with a delayed sweep that offers high performance and a built in component tester for capacitors, inductors, diodes, transistors, zener diodes. Specifications. Frequency Response 5 mV to 5 V/div: DC to 30 MHz (-3dB). Frequency Response X5: DC to 10 MHz (-3dB). Sensitivity: 5 mV/div to 5 V/div, 1 mV/div to 1 V/div at x5. Attenuator: 10 steps in 1-2-5 sequence. Vernier control provides full adjustment between steps. Accuracy: ±3%, ±5% at x5. Input impedance: 1 M-ohm ±2%. Input Capacitance: 25 pF ±10pF. Rise Time: 12 ns (Overshoot <=5%). Maximum Input Voltage: 400V (DC + AC peak). Sweep Operating Modes: Main, mix (both main sweep and delay sweep displayed), or Delay (only delay sweep displayed), X-Y. Triggering Modes: AUTO (free run) or NORM, TV-V, TV-H. X-Y Mode: Switch selectable using X-Y switch. CH 1: X axis, CH 2: Y axis. Accuracy: Y-Axis; ±3%, X-Axis; ±6%. Frequency Response: DC to 1MHz typical (-3 dB), to 6 div horizontal deflection. CRT Type: 6-inch rectangular with internal graticule. Components Tested: Resistors, capacitors, inductors, and semiconductors. Test Voltage: 6 V rms maximum (open). Test Current: 11 mA maximum (shorted).



 

Standard Calibration $255.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 2125A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your BK PRECISION 2125A CALIBRATION and/or BK PRECISION 2125A 2 Ch 30 MHz Delay Trace Analog Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: