BK PRECISION 2125A CALIBRATION and BK PRECISION 2125A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 2125A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   BK PRECISION 2125A   Description / Specification:   Spec Sheet 
BK PRECISION 2125A 2 Ch 30 MHz Delay Trace Analog Oscilloscope

The B+K Precision 2125A is a dual trace 30 MHz oscilloscope with a delayed sweep that offers high performance and a built in component tester for capacitors, inductors, diodes, transistors, zener diodes. Specifications. Frequency Response 5 mV to 5 V/div: DC to 30 MHz (-3dB). Frequency Response X5: DC to 10 MHz (-3dB). Sensitivity: 5 mV/div to 5 V/div, 1 mV/div to 1 V/div at x5. Attenuator: 10 steps in 1-2-5 sequence. Vernier control provides full adjustment between steps. Accuracy: ±3%, ±5% at x5. Input impedance: 1 M-ohm ±2%. Input Capacitance: 25 pF ±10pF. Rise Time: 12 ns (Overshoot <=5%). Maximum Input Voltage: 400V (DC + AC peak). Sweep Operating Modes: Main, mix (both main sweep and delay sweep displayed), or Delay (only delay sweep displayed), X-Y. Triggering Modes: AUTO (free run) or NORM, TV-V, TV-H. X-Y Mode: Switch selectable using X-Y switch. CH 1: X axis, CH 2: Y axis. Accuracy: Y-Axis; ±3%, X-Axis; ±6%. Frequency Response: DC to 1MHz typical (-3 dB), to 6 div horizontal deflection. CRT Type: 6-inch rectangular with internal graticule. Components Tested: Resistors, capacitors, inductors, and semiconductors. Test Voltage: 6 V rms maximum (open). Test Current: 11 mA maximum (shorted).



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 2125A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your BK PRECISION 2125A CALIBRATION and/or BK PRECISION 2125A 2 Ch 30 MHz Delay Trace Analog Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: