BK PRECISION 2160A CALIBRATION and BK PRECISION 2160A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 2160A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   BK PRECISION 2160A   Description / Specification:   Spec Sheet 
BK PRECISION 2160A 2 Ch 60 MHz Analog Oscilloscope

The B+K Precision 2160A 60 MHz Analog Oscilloscope includes a built in component tester, which is an excellent tool for in circuit troubleshooting. Specifications. Frequency Response: DC to 60 MHz (5 mV/div to 5 V/div), DC to 15 MHz (X5 MAG). Sensitivity: 5 mV/ 5 V/div, 1 mV/div to 1 V/div (X5 MAG). Attenuator: 1-2-5 sequence, plus x 5 gain step, Vernier control provide fully adjustable sensitivity between steps range 1/1 to at least 1/2.5. Accuracy: ±3%, 5 mV to 5 V/div; ±5%, 1 mV, 2 mV/div. Input impedance: 1 M-ohm ±2%. Input Capacitance: 25 pF±10%. Rise Time: 5.8 ns (Overshoot =5%). Operating Modes: CH1, CH2, Dual, Alternate Chop. Maximum Input Voltage: 400V (DC + AC peak). Sweep Display Modes: Main, Mix, Delay, XY. Main Sweep Speed: 0.1µs/div. to 2.0s/div. in 1-2-5 sequence, 23 steps. X-Y Mode: CH 1: X axis. CH 2: Y axis. Frequency Response: DC; DC to 1MHz (-3 dB), AC; 5 Hz or 2 MHz (-3 dB). CRT Type: 6-inch rectangular with internal graticule. Components Tested: Resistors, capacitors, inductors, and semiconductors. Test Voltage: 6 V rms maximum (open). Test Current: 11 mA maximum (shorted).



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 2160A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your BK PRECISION 2160A CALIBRATION and/or BK PRECISION 2160A 2 Ch 60 MHz Analog Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: