BK PRECISION 2522B CALIBRATION and BK PRECISION 2522B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 2522B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   BK PRECISION 2522B   Description / Specification:    
BK PRECISION 2522B 2 Ch 20 MHz Digital Storage/Analog Oscilloscope

The B+K Precision 2522B 20 MHz Digital Storage/Analog Oscilloscope includes all the basic features needed by most technicians and engineers. Unlike other digital oscilloscopes, it has a full analog mode with infinite resolution. Digital storage modes include refresh, roll, and single sweep. Equivalent time storage techniques allow storage of repetitive waveforms up to 20 MHz. The BK Precision 2522B has two vertical input channels for displaying two waveforms simultaneously. Selectable single trace (either CH 1 or CH 2) or dual trace. Alternate or chop sweep selectable at all sweep rates. Digital Mode Specifications. Storage Word Size: 2048 x 8 bits/channel; (2 k/channel with direct sampling, 1 k/channel with equivalent time sampling). Vertical Resolution: 1 in 256, approximately 25 steps/div. Horizontal Resolution: 1 in 2048, approximately 200 samples/div. Sampling Rate: 10 M samples/sec to 4 samples/sec, reduced in proportion to time base. Direct sampling at time base settings of 20 µs/div and slower, equivalent time sampling at time base settings of 10 µs/div and faster. Equivalent time Sampling Bandwidth: 20MHz for repetitive waveforms. Sweep Speed: 0.1 µs/div to 2 s/div in 1-2-5 sequence, 23 steps. Vernier control provides fully adjustable sweep time between steps. Accuracy: +3% Sweep Magnification: 10X, +6%. Hold off: variable. Triggering Modes: AUTO (free run) or NORM. Source: CH1, CH2, ALT, EXT, LINE. Analog Mode Specifications. Vertical Sensitivity: 5 mV/div to 5 V/div in 1-2-5 sequence, 10 steps. Vernier control provides fully adjustable gain between steps. Pull x5 increases maximum sensitivity to 1 mV/div (at reduced bandwidth). Accuracy: ±3%, ±5% at X5 MAG. Input Resistance: 1 M-ohm ±2%. Input Capacitance: 25 pF ±10 pF. Frequency Response: 5 mV to 5 V/div: DC to 20 MHz (-3 db). x5:DC to 10MHz (-3dB). Rise Time: Approximately 17.5 (Overshoot <= 3%). Maximum Input Voltage: 400 V (DC + AC peak). CRT Display Area: 8 x 10 div (1 div = 1 cm).



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 2522B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your BK PRECISION 2522B CALIBRATION and/or BK PRECISION 2522B 2 Ch 20 MHz Digital Storage/Analog Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: