BK PRECISION 2522B CALIBRATION and BK PRECISION 2522B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 2522B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   BK PRECISION 2522B   Description / Specification:    
BK PRECISION 2522B 2 Ch 20 MHz Digital Storage/Analog Oscilloscope

The B+K Precision 2522B 20 MHz Digital Storage/Analog Oscilloscope includes all the basic features needed by most technicians and engineers. Unlike other digital oscilloscopes, it has a full analog mode with infinite resolution. Digital storage modes include refresh, roll, and single sweep. Equivalent time storage techniques allow storage of repetitive waveforms up to 20 MHz. The BK Precision 2522B has two vertical input channels for displaying two waveforms simultaneously. Selectable single trace (either CH 1 or CH 2) or dual trace. Alternate or chop sweep selectable at all sweep rates. Digital Mode Specifications. Storage Word Size: 2048 x 8 bits/channel; (2 k/channel with direct sampling, 1 k/channel with equivalent time sampling). Vertical Resolution: 1 in 256, approximately 25 steps/div. Horizontal Resolution: 1 in 2048, approximately 200 samples/div. Sampling Rate: 10 M samples/sec to 4 samples/sec, reduced in proportion to time base. Direct sampling at time base settings of 20 µs/div and slower, equivalent time sampling at time base settings of 10 µs/div and faster. Equivalent time Sampling Bandwidth: 20MHz for repetitive waveforms. Sweep Speed: 0.1 µs/div to 2 s/div in 1-2-5 sequence, 23 steps. Vernier control provides fully adjustable sweep time between steps. Accuracy: +3% Sweep Magnification: 10X, +6%. Hold off: variable. Triggering Modes: AUTO (free run) or NORM. Source: CH1, CH2, ALT, EXT, LINE. Analog Mode Specifications. Vertical Sensitivity: 5 mV/div to 5 V/div in 1-2-5 sequence, 10 steps. Vernier control provides fully adjustable gain between steps. Pull x5 increases maximum sensitivity to 1 mV/div (at reduced bandwidth). Accuracy: ±3%, ±5% at X5 MAG. Input Resistance: 1 M-ohm ±2%. Input Capacitance: 25 pF ±10 pF. Frequency Response: 5 mV to 5 V/div: DC to 20 MHz (-3 db). x5:DC to 10MHz (-3dB). Rise Time: Approximately 17.5 (Overshoot <= 3%). Maximum Input Voltage: 400 V (DC + AC peak). CRT Display Area: 8 x 10 div (1 div = 1 cm).



 

Standard Calibration $255.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 2522B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your BK PRECISION 2522B CALIBRATION and/or BK PRECISION 2522B 2 Ch 20 MHz Digital Storage/Analog Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: