BK PRECISION 2706A CALIBRATION and BK PRECISION 2706A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 2706A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   BK PRECISION 2706A   Description / Specification:   Spec Sheet 
BK PRECISION 2706A Tool Kit DMM with Temperature

The B+K Precision 2706A Tool Kit DMM with Temperature is an excellent meter for most jobs that require flexibility, accuracy and speed. Specifications. DC Volts Ranges: 200 mV, 2 V, 20 V, 200 V, 1000 V. AC Volts Ranges: 200mV, 2 V, 20 V, 200 V, 750 V. DC Current Ranges: 200 µA, 2 mA, 20 mA, 200 mA, 2 A, 10 A. AC Current Ranges: 200 µA, 2 mA, 20 mA, 200 mA, 2 A, 10 A. Resistance Ranges: 200 ohm, 2 k-ohm, 20 k-ohm, 200 k-ohm, 2 M-ohm, 20 M-ohm. Diode Test: Tested at 1.6 mA and 3.2V Max. Transistor Test (hFE): Base Current: 10µA Vce; 2.8V; Gain Indication: 0 to 1,000. Capacitance Ranges: 2,000 pF, 2 nF, 20 nF, 200 nF, 2.0 uF, 20 uF. Frequency Ranges: 2 kHz, 20 kHz, 200 kHz, 2 MHz, 15 MHz. Temperature Range: -4° to + 1400°F (-20° to + 750°C). Continuity Tone: Tone Sounds within 100 mS for Resistance Under 100V. Display: 3 1/2 digit, high-contrast 0.7" LCD, 1999 counts. Sampling: 3 times/sec. (nominal).



 

Standard Calibration $80.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 2706A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your BK PRECISION 2706A CALIBRATION and/or BK PRECISION 2706A Tool Kit DMM with Temperature REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: