BK PRECISION 2831D CALIBRATION and BK PRECISION 2831D REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 2831D Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   BK PRECISION 2831D   Description / Specification:    
BK PRECISION 2831D 4 1/2 Digit True RMS Bench Multimeter

The BK Precision 2831D Digital multimeter is a portable, bench type Digital multimeter with a 4 1/2 digit light-emitting diode. This Digital multimeter can make diode measurements, Frequency measurements & continuity test, in addition to Current, Voltage and Resistance measurements. Features. Basic accuracy for DCV ; 0.05 %. Overload protection on all range. AC/DC Voltage measurement(Up to DC 1200V, AC 750V). AC/DC Current measurement (Up to 20 A). Resistance measurement (Up to 20 M-ohm). Frequency Measurement (Up to 200 KHz). Specifications. DC Volt Range: 2, 20, 200 V (Accuracy ±(0.05% + 5d)), 1200 V (Accuracy @ 1000 V ±(0.1% + 5d)). AC Volt Range (40 Hz to 60 Hz): 2, 20 V (Accuracy ±(0.75% + 10d)). AC Volt Range (50 Hz to 60 Hz): 200, 750 V (Accuracy ±(0.75% + 10d)). DC Current Range: 2, 20, 200 mA (Accuracy ±(0.75% + 5d)), 2 A (Accuracy ±(1.0% + 5d)), 20 A (Accuracy ±(1.0% + 10d)). AC Current Range (50 Hz to 60 Hz): 2, 20, 200 mA (Accuracy ±(0.75% + 10d)), 2000 mA, 20 A (Accuracy ±(1.0% + 10d)). Resistance Range: 2K, 20K, 200K, 2M ohm (Accuracy ±(0.2% + 6d)), 20M ohm (Accuracy ±(1% + 10d)). Frequency Range: 20 KHz (Accuracy ±(1.5% + 5d)), 200 KHz (Accuracy ±(2.0% + 5d)). Audible Continuity: 3 V, treshold Less Than 200 ohm. Diode Test 2V, Approx. 1.0 mA.



 

Standard Calibration $80.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 2831D. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your BK PRECISION 2831D CALIBRATION and/or BK PRECISION 2831D 4 1/2 Digit True RMS Bench Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: