BK PRECISION 4011A REPAIR and BK PRECISION 4011A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the BK PRECISION 4011A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 4011A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Function Generator?
Shop for Comparable Products on our
 used Function Generator page or new Function Generator page

 
   BK PRECISION 4011A   Description / Specification:   Spec Sheet 
BK PRECISION 4011A 5 MHz Function Generator

The B&K Precision 4011A 5 MHz Function Generator features Sine, Square, Triangle, Pulse & Ramp output, Variable duty cycle, Variable DC offset and a 4 digit LED display. Specifications. Frequency Range: 0.5 Hz to 5 MHz in 7 ranges. Waveforms: Sine, Square, Triangle, ±Pulse, ±Ramp. Resolution: 4 digits. Variable Duty Cycle: 15:85:15 cont variable. Output Impedance: 50 ohm ±10%. Level: 20 V p-p Open circuit, 10V p-p into 50 ohm. Amplitude: Variable, 20 dB range typical. Attenuation: -20 dB ±1dB. DC Offset: Preset ±0.1 V typ, Variable; ±10V open-circuit ±5 into 50 ohm. Sine Wave Distortion: <= 3% @ 1 kHz. Flatness: <= 5% (0.45 dB). Risetime (Into 50 ohms): <=20 nS. TTL Output Level: 0.8V to 2.4V. Rise time (0.8V to 2.9V): <= 20 nS. CMOS Output Max. Frequency: 2 MHz. Level: 4V to 14V ±0.5 p-p cont. variable. Rise Time: <= 120 nS. VCG Input Voltage: 0 to 10V ±1V causes a 100:1 frequency change. Frequency Counter INT Accuracy: Time Base Accy ±1 count. Time Base Accuracy: ±10 PPM (23°C ±5°C). Display: 4 digit LED.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 4011A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your BK PRECISION 4011A REPAIR and/or BK PRECISION 4011A 5 MHz Function Generator CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?