BK PRECISION 878 CALIBRATION and BK PRECISION 878 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 878 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   BK PRECISION 878   Description / Specification:    
BK PRECISION 878 120 Hz Handheld LCR Meter

The B+K Precision 878 Universal LCR Meter is a handheld instrument that will measure inductors, resistors and capacitors quickly and accurately. Utilizing special circuilIy, the measurement more closely replicates true in-circuit measurements. Ten range resistance range measures to 0.001 - zero adjust removes leads resistance. The four digit dual display feature permits simultaneous measurement of inductance and Q or capacitance and D (Dissipation Factor). Specifications. Capacitance Range: 0.1 pF to 10 mF. Resistance Range: 10 ohm to 10 M-ohm. Inductance Range: 1 mH to10,000 H. Test Frequency: 1 kHz and 120 Hz.



 

Standard Calibration $185.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 878. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your BK PRECISION 878 CALIBRATION and/or BK PRECISION 878 120 Hz Handheld LCR Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province:
Zip/Postal Code:
Phone:*

Comment: