BK PRECISION 886 CALIBRATION and BK PRECISION 886 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 886 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   BK PRECISION 886   Description / Specification:   Spec Sheet 
BK PRECISION 886 100 kHz Handheld Synthesized In-Circuit LCR/ESR Meter

The B&K Precision 886 synthesized in-circuit LCR/ESR meter has a wide range of test frequencies up to 100 kHz with many measurement parameters including Z, L, C, DCR, ESR, D, Q, and Ø as well. The 886 is designed for both component evaluation on the production line and fundamental impedance testing for benchtop applications. With a built-in direct test fixture, you can test the lead components very easily. The optional 4-wire test clip can give a convenient connection to larger components and assemblies with the accuracy of 4-wire testing. Specifications: Test Frequencies: 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz. Frequency Accuracy: ± 0.1%. Test Levels: 1 Vrms, 0.25 Vrms, 0.05 Vrms, 1 Vdc (for DCR). Level Accuracy: ± 5%. Output Impedance: 100 ohm, ± 5%. Impedance (Z) (Minimum 0.1 ohm to 20 M-ohm) Frequency Range: DCR, 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz (Minimum 0.1 ohm to 10 M-ohm) . Capacitance (C) Frequency Range (min to max): 100 Hz (15.91 mF to 79.57 pF), 120 Hz (13.26 mF to 66.31 pF), 1 kHz (1.591 mF to 7.957 pF), 10 kHz (159.1 µF to 0.795 pF), 100 kHz (15.91 µF to 0.159 pF). Inductance (L) Frequency Range (min to max): 100 Hz (31.83 kH to 159.1 µH), 120 Hz (26.52 kH to 132.6 µHF), 1 kHz (31.83 kH to 15.91 µH), 10 kHz (318.3 H to 1.591 µH), 100 kHz (31.83 H to 0.159 µH). Dual LCD display.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 886. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your BK PRECISION 886 CALIBRATION and/or BK PRECISION 886 100 kHz Handheld Synthesized In-Circuit LCR/ESR Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: