BOONTON 51075 CALIBRATION and BOONTON 51075 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BOONTON 51075 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Power Sensor?
Shop for Comparable Products on our
 used RF Power Sensor page

 
   BOONTON 51075   Description / Specification:    
BOONTON 51075 18 GHz Wide Dynamic Range Power Sensor

The Boonton 51075 Wide Dynamic Range Power Sensor is constructed using balanced diode detectors. This dual diode configuration offers increased sensitivity and harmonic suppression when compared to a single diode sensor. It is for use with models 4731, 4732, 4231A, 4232A, 4300, 4531, 4532, 5231, 5232, 5731, 5732. Specifications. Frequency Range: 500 kHz to 18 GHz. Dynamic Range -70 to +20 dBm. Overload Rating Peak Power: 1 W for 1µs. Overload Rating Continuous: 300 mW. Maximum SWR: to 2 GHz, 1.15; 2 to 6 GHz, 1.20; 6 to 18 GHz, 1.40. Drift Lowest Range (typ.) 1 Hour: 100 pW. Noise Lowest Range RMS (typical): 30 pW. Impedance: 50 ohm. RF Connector: Type N (M).



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BOONTON 51075. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your BOONTON 51075 CALIBRATION and/or BOONTON 51075 18 GHz Wide Dynamic Range Power Sensor REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: