DATRON 4700 REPAIR and DATRON 4700 CALIBRATION

 
Custom-Cal has a high success rate in the repair of the DATRON 4700. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the DATRON 4700 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibrator?
Shop for Comparable Products on our
 used Calibrator page

 
   DATRON 4700   Description / Specification:    
DATRON 4700 Multifunction Standard

Datron 4700 Multifunction Standard. DC Voltage; Ranges: 100 uV to 1000V in decades. Full scale: 2 x range except 1000V range, where max output 1100V. Resolution: 1 digit in 19,999,999 or 10 nV, whichever is greater. Sensing: Selectable remote/ local sensing on 1V to 1000V ranges. Guarding: Selectable remote/ local guarding. Settling Time: <1 s to 10 ppm of step size. Output Impedance/Max Output Current: 100 uV to 100 mV Ranges: 100 ohm. 1 V to 1000V Ranges: 25 mA max. AC Voltage Ranges: 1 mV to 1000V in decades. Full Scale: 2 x range except 1000V range, where max output 1100V. Resolution: 1 digit in 1,999 ,999 or 100 nV, whichever is greater. Frequency: Ranges: 100Hz to 1MHz in decade steps. Resolution: 1 % of range. Accuracy < ±100ppm. Sensing: Selectable remote/ local sensing on 1 V to 1000V ranges. Guarding: Selectable remote/ local guarding. Maximum Capacitive load: 1000 pF on 1V to 100V ranges, 300 pF on 1000V range. DC Current (Option 20); Ranges: 100 uA to 1 A in decades. Full scale: 2 x range. Resolution: 1 digit in 1,999,999 or 100 pA, whichever is greater. Guarding: Selectable remote/ local guarding. AC Current (Option 20); Ranges: 100 uA to 1 A in decades. Full scale: 2 x range. Resolution: 1 digit in 1,999,999 or 100 pA, whichever is greater. Guarding: Selectable remote/ local guarding. Resistance (Opt 20); Ranges: 10 ohm to 100M-ohm in decades. (Ranges are nominal, actual calibrated values are displayed). Connections: Selectable 2 or 4-wire, remote/local guard. Display Resolution: 1 digit in 19,999,999. Calibration: Autocal from front panel or via the IEEE-488 interface. OPTIONS; 10: 1000V Ranges for DCV and ACV. 20: DCI, ACI and ohm. 42: Alternative Rear Output.



 

Standard Cal with Data $1,305.00 *
*This is a Web introductory price for one calibration of the DATRON 4700. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your DATRON 4700 REPAIR and/or DATRON 4700 Multifunction Standard CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: