DATRON 4705 REPAIR and DATRON 4705 CALIBRATION

 
Custom-Cal has a high success rate in the repair of the DATRON 4705. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the DATRON 4705 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibrator?
Shop for Comparable Products on our
 used Calibrator page

 
   DATRON 4705   Description / Specification:    
DATRON 4705 Multifunction Programmable Calibrator

Datron 4705 is a low cost, fully multifunction, programmable calibrator. DC Voltage; Ranges: 100 uV to 1000V in decades. Full scale: 2 x range except 1000V range, where max output 1100V. Resolution: 1 digit in 1,999,999 or 10 nV, whichever is greater. Sensing: Selectable remote/ local sensing on 1V to 1000V ranges. Guarding: Selectable remote/ local guarding. Settling Time: <1 s to 10 ppm of step size. Output Impedance/Max Output Current: 100 uV to 100 mV Ranges: 100 ohm. 1 V to 1000V Ranges: 25 mA max. AC Voltage Ranges: 1 mV to 1000V in decades. Full Scale: 2 x range except 1000V range, where max output 1100V. Resolution: 1 digit in 199 ,999 or 1 uV, whichever is greater. Frequency: Ranges: 100Hz to 1MHz in decade steps. Resolution: 1 % of range. Accuracy < ±100ppm. Sensing: Selectable remote/ local sensing on 1 V to 1000V ranges. Guarding: Selectable remote/ local guarding. Maximum Capacitive load: 1000 pF on 1V to 100V ranges, 300 pF on 1000V range. DC Current; Ranges: 100 uA to 1 A in decades. Full scale: 2 x range. Resolution: 1 digit in 199,999 or 1nA, whichever is greater. Guarding: Selectable remote/ local guarding. AC Current; Ranges: 100 uA to 1 A in decades. Full scale: 2 x range. Resolution: 1 digit in 199,999 or 1nA, whichever is greater. Guarding: Selectable remote/ local guarding. Resistance; Ranges: 10 ohm to 100M-ohm in decades. (Ranges are nominal, actual calibrated values are displayed). Connections: Selectable 2 or 4-wire, remote/local guard. Display Resolution: 1 digit in 1,999,999. Calibration: Autocal from front panel or via the IEEE-488 interface. OPTIONS; 42: Alternative Rear Output.



 

Standard Cal with Data $1,305.00 *
*This is a Web introductory price for one calibration of the DATRON 4705. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your DATRON 4705 REPAIR and/or DATRON 4705 Multifunction Programmable Calibrator CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: