DESCO 19212 CALIBRATION and DESCO 19212 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the DESCO 19212 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   DESCO 19212   Description / Specification:    
DESCO 19212 Jewel Workstation Continuous Mini Monitor

The Desco 19212 Jewel Workstation Continuous Mini Monitor independently monitors the operator and the worksurface. The instant an operator’s wrist strap or cord fails, the monitor will issue audible and visual alarms alerting the user of the problem. In the same manner, the unit also confirms that a path to ground of less than 500 megohms exists from the ESD worksurface. The Jewel Workstation Continuous Monitor eliminates the need for periodic wrist strap tests and logging. Specifications. Test range of monitored circuit: 500K - 10M ohms. Worksurface Limit: Set to 500 Megohms ± 20%. Operating Voltage: 24VAC, 50-60 Hz. Wrist strap open circuit voltage: 1.2 volts peak to peak @ 1-2 MicroAmps. Mat test open circuit voltage: 5 to 7.5 volts. Response time to alarm: <50 mS. Operating Temperature: 32 - 100 F. Humidity Range: 0-95% RH, non-condensing.



 

Standard Calibration $80.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the DESCO 19212. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your DESCO 19212 CALIBRATION and/or DESCO 19212 Jewel Workstation Continuous Mini Monitor REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?