EXFO FOT-932 CALIBRATION and EXFO FOT-932 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EXFO FOT-932 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Fiber Optic Instrumentation?
Shop for Comparable Products on our
 used Fiber Optic Instrumentation page

 
   EXFO FOT-932 (FOT 932)   Description / Specification:    
EXFO FOT-932 MaxTester Multifunction Loss Tester

EXPO’s FOT-932 Multifunction Loss Tester is designed to help network service providers address CAPEX and OPEX issues, enable installers to easily adapt to all network types, and provide CATV operators with a single-unit solution to their back reflection, fiber length, high power and bidirectional loss measurement needs. Combined with its video fiber inspection probe, this unit also enables the easy detection of dirty or damaged connectors, providing a clear view of connectors and fiber ends on the FOT-932’s high-resolution display. The FOT-932 is a part of EXPO’s FOT-930 series.

Power Meter Specifications:
Detector type: Ge
Measurement range: 10 dBm to -70 dBm
Range displayed: ≥ -77 dBm
Uncertainty: ± 5% ± 0.1 nW
Wavelength range: 800 nm to 1650 nm
Display resolution: 0.01 dB
Recommended recalibration period: 3 years

Source Specifications:
Single-mode wavelengths: 1310 nm, 1490 nm, 1550 nm, 1625 nm
Single-mode wavelength uncertainty: ≤ ± 20 nm
Single-mode spectral width: ≤ 5 nm
Multi-mode wavelengths: 850 nm, 1300 nm
Multi-mode wavelength uncertainty: ≤ +50 nm, ≤ -25 nm
Multi-mode spectral width: ≤ 135 nm
Eight-hour stability: ± 0.05 dB

FasTest Specifications:
Loss Range: ≤ 60 dB
Side-by-side repeatability: 0.15 dB
Loopback repeatability: 0.25 dB
Single-mode length measurement range: 200 km
Multi-mode length measurement range: 5 km
Length measurement uncertainty: ± (10 m + 1% length)

ORL Specifications:
ORL range (APC / UPC): 65 dB / 55 dB
ORL uncertainty: ± 0.5 dB
Resolution: 0.01 dB

Talk Set Specifications:
Wavelength: 1550 ± 20 nm
Dynamic range: 45 dB

VFL Specifications:
Wavelength: 650 nm
Output power: 3 dBm



 

Standard Calibration $405.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the EXFO FOT-932. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Coherence Length
Average distance over which superimposed waves lose their phase relationships

Linewidth
Linewidth is the width of a spectral line in terms of wavelength, wave number and frequency.

Power Flatness Versus Wavelength
When changing the wavelength at constant power setting and recording the differences between actual and displayed power levels, the power flatness is ± half the span (in dB) between the maximum and the minimum of the measured power levels.

Spectral Width
Spectral Width is the wavelength interval over which the magnitude of all spectral components is equal to or greater than a specified fraction of the magnitude of the component having the maximum value. In optical communications applications, the usual method of specifying spectral width is the full width at half maximum. This is the same convention used in bandwidth, defined as the frequency range where power drops by less than half (at most -3 dB).

Telecom Bands
Optical fiber communications typically operate in a wavelength region corresponding to one of the following Bands. O Band (original): 1260–1360 nm. E Band (extended): 1360–1460 nm. S Band (short wavelengths): 1460–1530 nm. C Band (conventional): 1530–1565 nm. L Band (long wavelengths): 1565–1625 nm. U Band (ultralong wavelengths): 1625–1675 nm


Please contact us for your EXFO FOT-932 CALIBRATION and/or EXFO FOT-932 MaxTester Multifunction Loss Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: