A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EXFO PM-1102X Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Optical Power Meter?
Shop for Comparable Products on our
 used Optical Power Meter page or new Optical Power Meter page

 
   EXFO PM-1102X (PM 1102X)   Description / Specification:    
EXFO PM-1102X Single Channel Optical Power Meter

The Exfo PM-1102X Benchtop Optical Power Meter delivers accurate power measurements over a wide dynamic range along with high resolution and excellent linearity. Choose them for automatically measuring discrete values such as insertion loss or, alternately, for continuous monitoring and data acquisition. These stand-alone power meters provide exceptional performance, flexibility, user-friendliness and extensive integration capabilities. EXFO’s PM-1102X designed with the user in mind. A menu-driven interface guides you through the operation, displaying results clearly. Control your unit remotely with the GPIB and RS-232 interfaces and control codes from any compatible PC or test station. The Exfo PM-1102X Power Meter offers ±0.015 dB linearity with a ±5 % absolute uncertainty and a 0.001 dB power resolution. Whether you are measuring absolute or relative power levels, count on efficient, highly accurate measurements. With its fast stabilization time and high sampling rate, the PM-1102X Power Meter is ideal for system monitoring. To start your data acquisition and take full advantage of the high sampling rates, synchronize acquisitions using the two available trigger types. Select the PM-1100 when measuring high power (up to 20 dBm) in the 750 to 1700 nm wavelength range. The sensitivity of this detector is -75 dBm. Number of detectors: 1. Detector type: GeX. Detector size (mm): 2. Wavelength range (nm): 750 to 1700. Power range (dBm): 20 to -75. Uncertainty (%): ±5, (10 dBm to -35 dBm). Linearity (dB): ±0.015 (0 dBm to –35 dBm). Power resolution (dB): 0.001 (20 dBm to -35 dBm). Wavelength resolution (nm): 1. Fiber type (µm): 5/125 to 62.5/125.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the EXFO PM-1102X. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a fiber optic component, link or network will operate.

Extinction Ratio (ER)
Extinction Ratio is the ratio of two optical power levels, of a digital signal generated by an optical source, (example a laser diode), where P1 is the optical power level generated when the light source is "on," and P0 is the power level generated when the light source is "off." The extinction ratio may be expressed as a fraction, in dB, or as a percentage.

Optical Signal-to-noise Ratio (OSNR)
Optical Signal-to-noise ratio is the ratio between the signal power and the noise power in a given bandwidth. Most commonly a reference bandwidth of 0.1 nm is used. This bandwidth is independent from the modulation format, the frequency and the receiver. For instance a OSNR of 20dB/0.1nm could be given, even the signal of 40 GBit DPSK would not fit in this bandwidth. OSNR is measured with a Optical Spectrum Analyzer. It is generally measured at the wavelength of interest.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.

Wavelength Repeatability
Wavelength Repeatability is the random uncertainty in reproducing a wavelength after detuning and re-setting the wavelength. The wavelength repeatability is ± half the span between the maximum and the minimum value of all actual values of these wavelengths. Example test condition: uninterrupted TLS output power, constant power level, temperature within operating temperature range, coherence control off, short time span. Note: NOTE The long-term wavelength repeatability can be obtained by taken the wavelength repeatability and wavelength stability into account.


Please contact us for your EXFO PM-1102X CALIBRATION and/or EXFO PM-1102X Single Channel Optical Power Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?