FLUKE 12 CALIBRATION and FLUKE 12 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 12 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 12   Description / Specification:    
FLUKE 12 Handheld Digital Multimeter

The Fluke 12 Digital Multimeter is designed to support first level electrical and electronic troubleshooting. Their compact design, slide-switch and pushbutton controls allow true one-hand operation. V Chek simplifies safe power source and supply measurement. When measuring ohms/continuity with more than 4.5 volts present across the input jacks (intentional or not), the meter automatically switches to measuring ac or dc volts, whichever is greater. Input impedance is approximately 2 k-ohm, helping determine if voltage is from leakage or a hard connection. Overload protection is provided if the circuit is checked in ohms mode. Continuity Capture locates intermittent opens and shorts as brief as 250 us, and identifies them in a symbolic display. Min/Max recording with relative time clock, records highest and lowest voltage readings during a 100-hour period. Features. 4000 Count Digital Display. Diode Test. Fast Continuity Beeper. Sleep Mode. Specifications. VDC Range: 4.000 to 600 V. VDC Best Accuracy: ±(0.9% + 1). VDC Resolution: 1 mV. VAC Range: 4.000 to 600 V. VAC Best Accuracy: ±(1.9% + 3). VAC Resolution: 1 mV. Resistance Range: 400 ohm to 40 M-ohm. Resistance Best Accuracy: ±(0.9% + 1). Resistance Resolution: 0.1 ohm. Capacitance Range: 1.000 to 10,000 uF. Capacitance Best Accuracy: ±(1.9% + 2). Capacitance Resolution: 0.001 uF.



 

Standard Calibration $135.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 12. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your FLUKE 12 CALIBRATION and/or FLUKE 12 Handheld Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: