FLUKE 16 CALIBRATION and FLUKE 16 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 16 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 16   Description / Specification:    
FLUKE 16 Digital Multimeter with Temperature

The Fluke 16 Multimeter with Temperature defaults to autoranging when you turn it on. The 4000 mV range can be entered only with manual range selection. It is designed to Protection Class II requirement of UL3111, ANSI/ISA-S82, CSA C22.2 No 231, and VDE 0411, and IEC 1010 overvoltage Category III (CAT III, 600 Volts). Specifications. AC Voltage Ranges (50 to 400 Hz): 4000 mV, 4.000 V, 40.00 V, 400.0 V, 600 V. AC Voltage Maximum Resolution: 1 mV. AC Voltage Accuracy: ± (1.9% reading + 4). DC Voltage Ranges: 4000 mV, 4.000 V, 40.00 V, 400.0 V, 600 V. DC Voltage Maximum Resolution: 1 mV. DC Voltage Accuracy: ± (0.9% reading + 1) @ 40.00 V, 400.0 V, 600 V. Resistance Ranges: 400.0, 4.000 k, 40.00 k, 400.0 k, 4.000 M, 40.00 M ohm. Resistance Maximum Resolution: 0.1 ohm. Resistance Accuracy: ± (0.9% reading + 1 digits) @ 4.000 k, 40.00 k, 400.0 k, 4.000 M ohm. Capacitance Range: 1.000 µF, 10.00 µF, 100.0 µF, 10000 µF. Capacitance Maximum Resolution: 0.001 µF. Capacitance Accuracy: ±(1.9% + 2) @ 1.000 µF, 10.00 µF, 100.0 µF. Diode Range: 2.000V, 0.001 V resolution. AC µA (50 Hz to 400 Hz) Range: 0 to 200 µA. AC µA Resolution: 0.1 µA. AC µA Accuracy: ±(2% + 3 counts). DC µA Range: 0 to 200 µA. DC µA Resolution: 0.1 µA. DC µA Accuracy: ±(1% + 3 counts). Temperature Range: -10°C to 400°C, 14°F to 752°F. Temperature Resolution: 0.1°C or 0.2°F. Temperature (Type K Thermocouple) Range: -40°C to -10°C, -40°F to 14°F. Temperature (Type K Thermocouple) Resolution: 0.1°C or 0.2°F. MIN MAX Recording with Elapsed Time Range: 0 to 100 hours (99:59), 1 minute resolution. Maximum Voltage Between any Terminal and Earth Ground: 600V rms. Display: 3 3/4-digits, 4000 counts, updates 4/sec.



 

Standard Calibration $135.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 16. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your FLUKE 16 CALIBRATION and/or FLUKE 16 Digital Multimeter with Temperature REPAIR

I'm interested in: 
Calibration Type (Select one):
 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province:
Zip/Postal Code:
Phone:*

Comment: