FLUKE 337 CALIBRATION and FLUKE 337 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 337 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   FLUKE 337   Description / Specification:    
FLUKE 337 1000 Amp TRMS Clamp Type Meter

The Fluke 337 Clamp Meter measure inrush motor starting current the way a circuit breaker sees it. Small body and jaws fit perfectly in your hand and into tight places. Safety rating: IEC 1010-2-031, 600 V CAT III. Specifications. AC Current Range: 0 - 999.9 A. AC Current Accuracy: 2 % ± 5 counts (10 - 100 Hz). Crest Factor add 2% for CF > 2: 3 @ 500 A, 2.5 @ 600 A, 1.42 @ 1000 A. AC Response: True-rms. Inrush Integration Time: 100 ms. DC Current Range: 0 - 600.0 A. DC Current Accuracy: 2 % ± 5 counts. AC Voltage Range: 0 - 600.0 V. AC Voltage Accuracy: 1 % ± 5 counts (20 - 100 Hz). DC Voltage Range: 0 - 600.0 V. DC Voltage Accuracy: 1 % ± 5 counts. Resistance Range: 0 - 600.0 ohms, 600 - 6000 ohms. Resistance Accuracy: 1.5 % ± 5 counts. Continuity: <= 30 ohms. Hz Range: to 400 Hz. Hz Accuracy: 0.5 % + 5 counts.



 

Standard Calibration $115.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 337. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your FLUKE 337 CALIBRATION and/or FLUKE 337 1000 Amp TRMS Clamp Type Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: