FLUKE 705 CALIBRATION and FLUKE 705 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 705 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibrator?
Shop for Comparable Products on our
 used Calibrator page

 
   FLUKE 705   Description / Specification:    
FLUKE 705 Loop Calibrator

The Fluke 705 Loop Calibrator is an efficient tool for calibration, repair and maintenance of current loops. It features mA sourcing, simulation and measurement readout for quick, easy interpretation of readings, with 0.02% accuracy and 0.001 mA resolution and simultaneous mA and % of span display. This includes a "Span Check" for fast confirmation of zero and span. It also has a selectable slow ramp, fast ramp, and step to provide smooth outputs for valve slewing and loop functional tests, and a 24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM.
Specifications.

Current Measurement.
Range: 0 to 24 mA.
Resolution: 0.001 mA.
Accuracy: 0.02% Rdg + 2 LSD.

Current Sourcing
Range: 0 to 20 mA or 4 to 20 mA.
Accuracy: 0.025% Rdg + 2 LSD.
Drive Capability: 1000 Ω @ 24 mA.

Current Simulation
Range: 0 to 20 mA or 4 to 20 mA.
Accuracy: 0.025% Rdg + 2 LSD.
Ext. loop voltage requirement: 12-30 V.
Loop Power: While measuring mA, 24 V.

Voltage measurement
Range: 0 to 28 V DC.
Resolution: 1 mV.
Accuracy: 0.025% Rdg + 2 LSD.



 

Standard Calibration $650.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 705. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your FLUKE 705 CALIBRATION and/or FLUKE 705 Loop Calibrator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: