FLUKE 1587 CALIBRATION and FLUKE 1587 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 1587 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 1587   Description / Specification:    
FLUKE 1587 Handheld Digital Insulation Multimeter

The Fluke 1587 is a handheld digital insulation multimeter with a wide range of functions icluding DC/AC voltage and current, resistance continuity, frequency, diode test, temperature and Min/Max. DC voltage max reading: 1000 V with an accuracy of +/-(0.09%+2) and a max resolution of 0.001 V. AC voltage max reading: 1000 V with an accuracy of +/-(2%+3) and a maximum resolution of 0.1 mV, with a bandwidth of 5 kHz. DC current maximum reading: 400 mA with an accuracy of +/-(0.2%+2) and a max resolution of 0.01 mA. AC current maximum reading: 400 mA with an accuracy of +/-(1.5%+2) with a max resolution of 0.01 mA and a 1 kHz bandwidth. Maximum resistance reading: 50 mega-ohms, with an accuracy of +/-(0.9%+2) and max resolution of 0.1 ohms. Capacitance maximum reading: 9999 micro-farads with an accuracy of +/-(1.2%+2) and a mx resolution of 0.01 Hz. Maximum frequency reading of 100 kHz with an accuracy of +/-(0.1%+1) and a max resolution of 0.01 Hz. Temperature measurement range: -40.0 to 537 degrees C, or -40.0 to 998 degrees F. Diode test range: 6 V, with a resolution of 1 mV and an accuracy of +/-(2%+1). Insulation test minimum test current: 1 mA. Test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V. Max resistance per test voltage: 2 giga-ohms (at 1000 V). Maximum resolution per test voltage: 0.01 mega-ohms (50 V), 0.01 mega-ohms (100 V), 0.1 mega-ohm (250 V), 0.1 mega-ohm (500 V), 0.1 mega-ohm (1000 V). Accuracy per test voltage: +/-(3%+5) at 50 V, +/-(3%+5) at 100 V, +/-(1.5%+5) at 250 V, +/-(1.5%+5) at 500 V, +/-(1.5%+5) to 600 mega-ohms, +/-(10%+3) above 600 mega-ohms at 1000 V. Meter use with new batteries: 1000 hours.



 

Standard Calibration $260.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 1587. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your FLUKE 1587 CALIBRATION and/or FLUKE 1587 Handheld Digital Insulation Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: