FLUKE 21 II CALIBRATION and FLUKE 21 II REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 21 II Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 21 II   Description / Specification:    
FLUKE 21 II Handheld Analog / Digital Multimeter

The Fluke 21 II Analog/Digital Multimeter provides a wealth of automatic features, measurement capabilities, and accuracy ranges. Features. 31-Segment analog bar graph, allowing greater flexibility than traditional 3.5 digit DMMs. Single pushbutton and rotary dial to select all functions. Automatic Touch Hold captures stable readings. Auto and manual ranging and automatic polarity selection. Diode test/audible continuity beeper enables fast continuity checks and audible notification of voltage drops of less than 0.7 volts. Sleep Mode to preserve battery life. All ranges for 21 II Multimeter is protected against overloads, including a fused 10 amp range for each model. All voltage inputs are protected to recover or fail safe from power line-surges from major feeders, as defined in IEEE-587-1980, Category B, which includes simulated lightning and load switching transient pulses up to 6 kV superimposed on 660V power lines. Digital Display / Counts 3200. Specifications. VDC Range: 320 mV to 1000 V. VDC Best Accuracy: ±(0.4% + 1). VDC Resolution: 1 mV. VAC Range: 3.2 to 750 V. VAC Best Accuracy: ±(2% + 2). VAC Resolution: 1.0 mV. ADC Range: 32 mA to 10 A. ADC Best Accuracy: ±(1.5% + 2). ADC Resolution: 0.01 mA. AAC Range: 32 mA to 10 A. AAC Best Accuracy: ±(2.5% + 2). AAC Resolution: 0.01 mA. Resistance Range: 320 ohm to 32 M-ohm. Resistance Best Accuracy: ±(0.5% + 1). Resistance Resolution: 0.1 ohm.



 

Standard Calibration $135.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 21 II. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your FLUKE 21 II CALIBRATION and/or FLUKE 21 II Handheld Analog / Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: