FLUKE 23 II CALIBRATION and FLUKE 23 II REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 23 II Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 23 II   Description / Specification:    
FLUKE 23 II Handheld Analog / Digital Multimeter

The Fluke 23 II Analog/Digital Multimeter provides a wealth of automatic features, measurement capabilities, and accuracy ranges. Features. 31-Segment analog bar graph, allowing greater flexibility than traditional 3.5 digit DMMs. Single pushbutton and rotary dial to select all functions. Automatic Touch Hold captures stable readings. Auto and manual ranging and automatic polarity selection. Diode test/audible continuity beeper enables fast continuity checks and audible notification of voltage drops of less than 0.7 volts. Sleep Mode to preserve battery life. All ranges for 23 II Multimeter is protected against overloads, including a fused 10 amp range for each model. All voltage inputs are protected to recover or fail safe from power line-surges from major feeders, as defined in IEEE-587-1980, Category B, which includes simulated lightning and load switching transient pulses up to 6 kV superimposed on 660V power lines. Digital Display / Counts 3200. Specifications. VDC Range: 320 mV to 1000 V. VDC Best Accuracy: ±(0.3% + 1). VDC Resolution: 1 mV. VAC Range: 3.2 to 750 V. VAC Best Accuracy: ±(2% + 2). VAC Resolution: 1.0 mV. ADC Range: 32 mA to 10 A. ADC Best Accuracy: ±(1.5% + 2). ADC Resolution: 0.01 mA. AAC Range: 32 mA to 10 A. AAC Best Accuracy: ±(2.5% + 2). AAC Resolution: 0.01 mA. Resistance Range: 320 ohm to 32 M-ohm. Resistance Best Accuracy: ±(0.5% + 1). Resistance Resolution: 0.1 ohm.



 

Standard Calibration $135.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 23 II. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your FLUKE 23 II CALIBRATION and/or FLUKE 23 II Handheld Analog / Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: