FLUKE 5100B REPAIR and FLUKE 5100B CALIBRATION

The FLUKE 5100B is currently in stock and available for purchase on our  Sales Page
It is also available for immediate rental.
Custom-Cal has a high success rate in the repair of the FLUKE 5100B. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 5100B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibrator?
Shop for Comparable Products on our
 used Calibrator page

 
   FLUKE 5100B   Description / Specification:    
FLUKE 5100B Five-function Calibrator, AC/DC Voltage AC/DC Current Resist

The Fluke 5100B is a five-function calibrator built for electrical calibration. It calibrates analog and digital multimeters to 4.5 digits, precision meters that measure ac or dc voltage (0-1100V), ac or dc current (200 uA-2A), and resistance (1 ohm to 10 Mohms).
Specifications.

Voltage DC Ranges/ Resolution:
  20 mV / 0.1 μV,
  200 mV / 1 μV,
  2 V / 10 μV,
  20 V / 100 μV,
  200 V / 1 mV,
  1100 V / 10 mV.
Uncertainty: ±(0.004% of setting +0 .001 % of range +5 μV) for all ranges, for 6 months, 20°C to 30°C ambient, non-override; ±(0.005% of setting +0.2 mV) for divider override mode.

Voltage AC Ranges/ Resolution:
  20 mV / 0.1 μV,
  200 mV / 1 μV,
  2 V / 10 μV,
  20 V / 100 μV,
  200 V / 1 mV,
  1100 V / 10 mV.
Uncertainty: ±(0.035% of setting +0.005% of range +50 μV) from 50 Hz to 10kHz and ±(0.06% of setting +0.008% of range +50 μV) from 10kHz to 50 kHz for 6 months, 20°C to 30°C ambient.
Frequencies Available (Hz): 50, 60, 70, 80, 90, 100, 200, 300, 400, 500, 600, 700, 800, and 900 for all voltage ranges.

Current DC Ranges/ Resolution:
  200 μA / 1 nA,
  2 mA / 10 nA,
  20 mA / 100 nA,
  200 mA / 1 μA,
  2 A / 10 μA.
Uncertainty: ±0.015% of setting +0.002% of range +0.01 μA) for compliance voltage up to 1 V; Add 0.002% of setting per volt above 1 V rms; Applies for 6 months and 20°C to 30°C ambient

Current AC Ranges/ Resolution:
  200 μA / 1 nA,
  2 mA / 10 nA,
  20 mA / 100 nA,
  200 mA / 1 μA,
  2 A / 10 μA.
Uncertainty: ±0.05% of setting +0 .005% of range +0.02 μA) for compliance voltage up to 1 V rms (50 Hz to 1 kHz). Add 0.005% of setting per volt above 1 V rms. Applies for 6 months in 20°C to 30°C ambient.

Resistance:
Range: 1 Ω to 10 MΩ in decade steps.
Uncertainty: ±0.003%, except ±0.015% (1 Ω), ±0.010% (10 Ω and 1 MΩ), and ±0.030% (10 MΩ) assumes 4 terminal below 100 kΩ. 6 mo 20°- 30°C.
Power Dissipation: 1W maximum except 100 mW max (1 MΩ) and 10 mW max (10 MΩ).

Options.
-03 Wide band AC Voltage.
-05 IEEE-488 Compatible Interface.
-06 EIA RS-232-C Interface.



 

Standard Calibration $890.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 5100B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your FLUKE 5100B REPAIR and/or FLUKE 5100B Five-function Calibrator, AC/DC Voltage AC/DC Current Resist CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: