FLUKE 5500A REPAIR and FLUKE 5500A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the FLUKE 5500A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 5500A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibrator?
Shop for Comparable Products on our
 used Calibrator page

 
   FLUKE 5500A   Description / Specification:    
FLUKE 5500A Multi-Product Calibrator

The Fluke 5500A Multi-Product Calibrator can calibrate digital and analog multimeters, thermometers (thermocouple and RTD) handheld wattmeters, data loggers, current clamps, various types of recorders, panel meters, process calibrators, power harmonics analyzers and many other similar measurement tools.
Specifications.

Voltage DC;
  Range: 0 to ±1,200V.
  Best 1 Year Specification: ±50.0 ppm of setting.

Current DC;
  Range: 0 to ±11A.
  Best 1 Year Specification: ±0.01% of setting.

Resistance;
  Range: 0 to 3.29.999 MΩ.
  Best 1 Year Specification: ±0.009% of setting.

Voltage AC;
  Range: 1 mV to 1,020V, 10 Hz to 500 kHz, Sine.
  Best 1 Year Specification: ±0.03% of setting.

Current AC;
  Range: 29 mA to 11A, 10 Hz to 10 kHz, Sine.
  Best 1 Year Specification: ±0.06% of setting.

Capacitance;
  Range: 0.33 nF to 1.1 mF.
  Best 1 Year Specification: ±0.25% of setting.

Thermocouple Source and Measure;
  Range: -250°C to +2,316°C (11 types).
  Best 1 Year Specification: ± 0.14°C of setting.

RTD Source;
  Range: -200°C to +630°C (8 types).
  Best 1 Year Specification: ±0.03°C of setting.

DC Power;
  Range: 109 uW to 11 kW.
  Best 1 Year Specification: ± 0.08% of setting.

AC Power;
  Range: 109 uW to 11 kW, 45-65 Hz, PF=1.
  Best 1 Year Specification: ± 0.15% of setting.

Phase;
  Range: 0 to ± 179.99°.
  Best 1 Year Specification: ±25 ppm of setting.

Frequency;
  Range: 0.01 Hz to 2.0 MHz.
  Best 1 Year Specification: ±25 ppm of setting.

Options.
5500A/COIL 50 Turn Current Coil for calibrating clamp type current meters.
5500A-SC300 300 MHz Oscilloscope Calibration.
5500A-SC600 600 MHz Oscilloscope.
5725A Amplifier extends the Volt*Hertz product.



 

Standard Cal with Data $1,490.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 5500A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your FLUKE 5500A REPAIR and/or FLUKE 5500A Multi-Product Calibrator CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: