FLUKE 77 II CALIBRATION and FLUKE 77 II REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 77 II Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 77 II (77-II)   Description / Specification:    
FLUKE 77 II Handheld Analog / Digital Multimeter

The Fluke 77 II Analog/Digital Multimeter is suitable for measurements in protected circuits, which do not exceed 4800 VA, the 77 II provides a wealth of automatic features, measurement capabilities, and accuracy ranges. Features. 31-Segment analog bar graph, allowing greater flexibility than traditional 3.5 digit DMMs. Automatic Touch Hold captures stable readings. Single pushbutton and rotary dial to select all functions. Auto and manual ranging and automatic polarity selection. Diode test/audible continuity beeper enables fast continuity checks and audible notification of voltage drops of less than 0.7 volts. Sleep Mode to preserve battery life. All inputs protected (including 10 A). Digital Display / Counts 3200. Specifications. VDC Range: 320 mV to 1000 V. VDC Best Accuracy: ±(0.3% + 1). VDC Resolution: 1 mV. VAC Range: 3.2 to 750 V. VAC Best Accuracy: ±(2% + 2). VAC Resolution: 1.0 mV. ADC Range: 32 mA to 10 A. ADC Best Accuracy: ±(1.5% + 2). ADC Resolution: 0.01 mA. AAC Range: 32 mA to 10 A. AAC Best Accuracy: ±(2.5% + 2). AAC Resolution: 0.01 mA. Resistance Range: 320 ohm to 32 M-ohm. Resistance Best Accuracy: ±(0.5% + 1). Resistance Resolution: 0.1 ohm.



 

Standard Calibration $70.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 77 II. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your FLUKE 77 II CALIBRATION and/or FLUKE 77 II Handheld Analog / Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: