FLUKE 79 III CALIBRATION and FLUKE 79 III REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 79 III Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 79 III (79-III)   Description / Specification:    
FLUKE 79 III Digital Multimeter

The Fluke 79 III Digital Multimeter has all ranges protected against overloads: voltages to 1000V dc, 1000V ac; resistance to 1000 V. All current inputs are protected with high energy fuses - including the 10 amp range. Specifications. DC Voltage Ranges: 40.00 mV, 400.0 mV, 4.000V, 40.00V, 400.0V, 1000V. DC Voltage Maximum Resolution: 0.01 mV. DC Voltage Accuracy: ± (0.3% reading + 1) @ 4.000 V. AC Voltage Ranges (45 Hz to 1 kHz): 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V. AC Voltage Maximum Resolution: 0.1 mV. AC Voltage Accuracy: ± (1.9% reading + 4) @ 400 mV. DC Current Ranges: 4.000 mA, 40.00 mA, 4 A, 10.00 A. DC Current Maximum Resolution: 0.001 mA. DC Current Accuracy: ±(1.5% + 4) @ 4.000 mA. AC Current Ranges (45 Hz to 1 kHz): 4.000 mA, 40.00 mA, 4 A, 10.00 A. AC Current Maximum Resolution: 0.001 mA. AC Current Accuracy: ±(0.5% + 5) @ 4.000 mA. Resistance Ranges: 400.0, 4.000 k, 40.00 k, 400.0 k, 4.000 M, 40.00 M ohm. Resistance Maximum Resolution: 0.1 ohm. Resistance Accuracy: ± (0.4% reading + 2 digits) @ 400 ohm. Frequency Counter: 1.0 Hz to 20 kHz. Diode Range: 2.450 V. Display Digital: 4000 counts, updates 4/sec. Display Analog: 63 segments, updates 40/sec. Display Frequency: 9,999 counts. Display Capacitance: 9,999 counts. Response Time of Digital Display: VAC <1.5 s (for upscale only), VDC <1 s, ohms <1 s to 40 kohms, <2 s to 4 Mohms, <10 s to 40 Mohms.



 

Standard Calibration $135.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 79 III. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your FLUKE 79 III CALIBRATION and/or FLUKE 79 III Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: