FLUKE 8060A REPAIR and FLUKE 8060A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the FLUKE 8060A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 8060A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 8060A   Description / Specification:    
FLUKE 8060A 4 1/2 Digit TRMS Digital Multimeter

The Fluke 8060A 4 1/2-digit DMM offers more measurement capabilities than many bench/portable models. Well suited for engineers and technicians working in audio, video, telecommunications, or computer technology, both meters combine precision and accuracy with a wealth of features to fit nearly every application. True-rms ac voltage and current measurement. Fast audible-visual continuity tests. Relative Reference (offset). When measuring ohms with the 8060A the relative reference function displays only the difference between a stored reference value and a measured value, even if the range was changed between readings. Relative mode works in all functions and ranges. Specifications. VDC Range: 200 mV - 1000 V. VDC Best Accuracy: ±(0.04% + 2). VDC Resolution: 10 uV. VAC (True-RMS, AC Coupled) Range: 200 mV - 1000 V. VAC Best Accuracy: ±(0.2% + 10). VDC Resolution: 10 uV. dBm, 600 ohm Reference Range: -50 - +60 dBm. dBm Best Accuracy: ± (0.15 dB). dBm Resolution: 0.01 dB. ADC Range: 200 uA - 2000 mA. ADC Best Accuracy: ±(0.2% + 2). ADC Resolution: 0.01 uA. AAC (True-RMS) Range: 200 uA - 2000 mA. AAC Best Accuracy: ±(0.75% + 10). AAC Resolution: 0.01 uA. Resistance Range: 200 ohm - 300 M-ohm. Resistance Best Accuracy: ±(0.07% + 2). Resistance Resolution: 0.01 ohm. Frequency 12 Hz to >200 kHz Range: 200 Hz - 200 kHz. Frequency Best Accuracy: ±(0.05% + 1). Frequency Resolution: 0.01 Hz. Conductance Range: 2000 nS (equivalent to 500 k-ohm). Conductance Best Accuracy: ±(0.5% + 20). Conductance Resolution: 0.01 Hz (equivalent to 10,000 M-ohm).



 

Standard Calibration $70.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 8060A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your FLUKE 8060A REPAIR and/or FLUKE 8060A 4 1/2 Digit TRMS Digital Multimeter CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: