FLUKE 867B CALIBRATION and FLUKE 867B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 867B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 867B   Description / Specification:    
FLUKE 867B Graphical Multimeter

The Fluke 867B is a high precision Graphical Multimeter. It features 0.025% basic dc accuracy to discriminate low-level signal variations in transducers and analog electronics, measuring True-rms ac with bandwidth to 300 kHz, direct current from 0 to 10 Amps, with resolution down to 10nA, capacitance from 40pF to 10,000 µF., and dB gain or loss in amplifiers, filters, or attenuators. It also features an RS-232 Interface for communication to computers and printers and to import waveforms into reports. It is safety tested for IEC 1010-1, CAT III 1000 Volts for industrial distribution systems.
Specifications.

DC Voltage.
  Measurement Range: 300.00 mV to 1000.0V.
  Basic Accuracy: ±0.025%.
AC Voltage RMS.
  Measurement Range: 300.00 mV to 1000.0V.
  Basic Accuracy: ±0.5%.
  Bandwidth: 20 Hz to 300 Khz.
  AVG Bandwidth: 50 Hz to 30 Khz.
DC Current.
  Measurement Range: 300.00 µA to 10.000A.
  Basic Accuracy: ±0.05% to 0.2% N/A.
AC Current.
  Measurement Range: 300.00 µA to 10.000A.
  Basic Accuracy: ±0.75% N/A.
Resistance.
  Measurement Range: 300.00 Ohm to 30.000 MOhm.
  Basic Accuracy: ±0.07%.
Frequency.
  Measurement Range: 2 Hz to 2 MHz.
  Basic Accuracy: ±0.05%.
Capacitance.
  Measurement Range: 10 nF to 10,000 µF.
  Basic Accuracy: ±1.90%.
Waveform Display: 1 MHz.
Peak Hold: Captures positive and negative peaks ³ 10 µs.
Glitch Capture: Captures glitches ³ 1 µs.
dB/dBm.
  Measurement Range: 2, 4, 8, 16, 50, 75, 93, 110, 125, 135, 150, 300, 600, 900, 1000, 1200 Ohm references.
  Basic Accuracy: ±0.05dB.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your FLUKE 867B CALIBRATION and/or FLUKE 867B Graphical Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: