FLUKE 287 CALIBRATION and FLUKE 287 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 287 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 287   Description / Specification:    
FLUKE 287 True-rms Industrial Logging Multimeter with TrendCapture

The Fluke 287 True-rms Industrial Logging Multimeter with TrendCapture maximizes plant productivity in the most demanding industrial settings. Solve problems on motor drives, in-plant automation, power distribution and electro-mechanical equipment. It has a large 50,000 count, 1/4 VGA display with white backlight for fast, accurate viewing of measurements. The Logging Function with TrendCapture plots measurements as a single line to help detect anomalies over time, storing up to 10,000 readings. Using on-board TrendCapture, you can graphically view logged readings on the meter. Specifications. DC Volts Range & Resolution: 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V. DC Volts Basic Accuracy: 0.025 %. AC Volts Range & Resolution: 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V. DC Volts Basic Accuracy: 0.4 % (true-rms). DC Current Range & Resolution: 500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A. DC Current Basic Accuracy: 0.15 %. AC Current Range & Resolution: 500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A. AC Current Basic Accuracy: 0.7 % (true-rms). Temperature (excluding probe): -200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F). Temperature Basic Accuracy: 1.0 %. Resistance Range & Resolution: 50.000 ohm, 500.00 ohm, 5.0000 kohm, 50.000 kohm, 500.00 kohm, 5.0000 Mohm, 50.00 Mohm, 500.0 Mohm. Resistance Basic Accuracy: 0.05 %. Capacitance Range & Resolution: 1.000 nF,10.00 nF 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 1000 µF, 10.00 mF, 100.00 mF. Capacitance Basic Accuracy: 1.0 %. Frequency Range & Resolution: 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz. Frequency Basic Accuracy: 0.005 %. Continuity/Diode Conductance: 0.01 nS to 50.00 nS (20 Mohm to 100 Gohm).



 

Standard Calibration $230.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 287. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your FLUKE 287 CALIBRATION and/or FLUKE 287 True-rms Industrial Logging Multimeter with TrendCapture REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: