FLUKE 77 IV CALIBRATION and FLUKE 77 IV REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 77 IV Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 77 IV (77-IV)   Description / Specification:    
FLUKE 77 IV Digital Multimeter

The Fluke 77-IV Digital Multimeter is a battery-powered, average responding-rms indicating multimeter with a 6000-count, 3 3/4-digit display, and a bar graph. It meets ANSI / ISA S82.02.01, CSA C22.2-1010.1, IEC 61010 to 1000 V Measurement Category III, 600 V Measurement Category IV.
Specifications.

Voltage DC.
Range: 6.000 V - 1000 V.
Best accuracy: ±(0.3% + 1).
Best resolution: 0.1 mV.

Voltage AC.
Range: 600.0 mV - 1000V.
Best accuracy: ±(2.0% + 2).
Best resolution: 1.0 mV.

Amps AC.
Range: 60.00 mA - 10 A.
Best accuracy: 2.5% + 2.
Best resolution: 0.01 mA.

Amps DC.
Range: 60.00 mA - 10A.
Best accuracy: 1.5% + 2.
Best resolution: 0.01 mA.

Resistance.
Range: 600.0 Ω - 50 MΩ.
Best accuracy: ±(0.5% + 1).
Best resolution: 0.1 Ω.

Capacitance.
Range: 1nF - 9,999 μF.
Best accuracy: ±(1.2% + 2).
Best resolution: 1 nF.

Frequency.
Range: 99.99Hz - 99.99kHz.
Best accuracy: ±(0.1% + 1).
Best resolution: 0.01 Hz.



 

Standard Calibration $135.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 77 IV. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your FLUKE 77 IV CALIBRATION and/or FLUKE 77 IV Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: