FLUKE 1550B CALIBRATION and FLUKE 1550B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 1550B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   FLUKE 1550B   Description / Specification:    
FLUKE 1550B 5000V MegOhmMeter

The Fluke 1550B MegOhmMeter provides for powerful troubleshooting and predictive maintenance capability. Features. Standard test voltages of 250 V, 500 V, 1000 V, 2500 V and 5000 V for a wide range of equipment testing. Programmable test voltages available in 50 volt steps from 250 to 1000 volts and 100 volt steps from 1000 to 5000 volts. Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup. Easy set-ups save time and effort when conducting “timed” and “ramp” test of insulation breakdown. Improved ramp function (0 to 5000 V dc) for breakdown testing. Autodischarge of capacitive voltage. Measures resistances up to one teraohm. Measures cable or insulation capacitance and leakage current. Warning voltage function alerts the user that voltage is present and gives the voltage reading up to 600 V ac or dc. Guard system eliminates the effect of surface leakage current on high-resistance measurements. Measurements can now be stored in up to 99 memory locations, with each location assigned a unique, user defined, four character (alpha-numeric) label for easy recall. Specifications. Insulation Resistance Measurement Test Voltage (dc): 250 to 5000 V. Insulation Resistance Measurement Ranges: 200 kohm to 1 Tohm. Short circuit current: greater than 1 mA and less than 2 mA. Bargraph range: 0 to 1 Tohm. Insulation test voltage accuracy: -0 % to +10 % at 1 mA load current. Induced ac mains current rejection: 2 mA maximum. Charging rate for capacitive load: 5 seconds per µF. Leakage current Range: 1 nA to 2 mA, (Accuracy ± (5 % + 2 nA)). Capacitance measurement Range: 0.01 uF to 15.00 µF, (Accuracy ± (15 % rdg + 0.03 µF)). Live circuit indicator Range: 30 V to 600 V ac/dc, 50/60 Hz (Accuracy ± (5 % + 2V)).



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 1550B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your FLUKE 1550B CALIBRATION and/or FLUKE 1550B 5000V MegOhmMeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: