ADVANTEST Q8384 REPLACEMENT / ALTERNATE

Custom-Cal has a solution to replace your ADVANTEST Q8384. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

The Deviser Optical Spectrum Analyzer is a Monochromatic (Grating Filter) type OSA designed to cover O,C and L optical communication bands as well as visible light starting at 600nM.  (600 ~ 1700nm).    Specification are comparable to the latest model in the Yokogawa AQ6370 series at a price that fits your budget.  Some measurement types this OSA can easily accommodate are: Optical Amplifier (EDFA) Measurement, Fabry-Perot Laser Diode (FP LD) Analysis, Distributed Feedback Laser Diode (DFB LD) Analysis, Gas measurement, Wavelength-Division Multiplexing (WDM) Channel Analysis and Notch Width Measurement.
Original
Replacement
  
ADVANTEST Q8384 600 to 1750 nm Optical Spectrum Analyzer

DEVISER AE8600 600 to 1700 nm Optical Spectrum Analyzer

ADVANTEST Q8384   Description / Specification: DEVISER AE8600   Description / Specification:      
The Advantest Q8384 is a high-end optical spectrum analyzer using a monochromator developed by ADVANTEST and featuring a high dynamic range and a high wavelength resolution. It offers the highest level of performance with a 10pm wavelength resolution and a 20pm wavelength accuracy in the 1.55µm band. This enables precise measurement and evaluation of wavelength characteristics. The Q8384 has a wide dynamic range of 60dB at 0.2nm from the peak wavelength. Q8384 also integrates automatic NF measurement and arithmetic functions for optical fiber amplifiers with easy operation. Wavelengths can be measured with accuracy of ±20pm at 1530nm to 1570nm and ±40pm in the L band at 1570nm to 1610nm after calibration using a built-in calibration light source (Option 25). This enables high-spec laser diodes and optical filters used in DWDM to be evaluated accurately. The wavelength linearity is ±10pm at 1530nm to 1570nm enabling the spacing of wavelength-multiplexed signals to be measured accurately. Specifications. Wavelength Measurement range: 600 to 1700 nm. Wavelength Accuracy: <= ± 500 pm. Wavelength Linearity: <= ± 10 pm (1530 to 1570 nm). Wavelength Repeatability: <= ± 3 pm (1530 to 1610 nm). Wavelength Resolution Setting: 10 pm, 20 pm, 50 pm, 100 pm, 200 pm, 500 pm. Level Measurement range: -87 to +23 dBm (1250 to 1610 nm). Level Accuracy: <= ± 0.4 dB (1550 nm). Level Linearity: <= ± 0.05 dB (-50 to -10 dBm, 1550 nm). Level Repeatability: <= ± 0.02 dB (1530 to 1610 nm). Level Flatness: <= ± 0.2 dB (1530 to 1610 nm). Level Polarization dependence: <= ± 0.05 dB (1250 to 1610 nm). Level Dynamic range: 50 dB (at ± 100pm from peak wavelength). Sweep Span: From 0.2nm to full span and zero. Sweep Number of samples: 101, 201, 501, 1001, 2001, 500.


The Deviser E8600 is a high-precision diffraction-grating, high-resolution optical spectrometer with wavelength range of 600 nm to 1700 nm. The 10.1” LCD touchscreen and concise graphical user interface of AE8600 offer the easiest way to handle optical spectrum analysis. It provides a wide selection of test methodology, including laser spectrum scans (DPB, FP), WDM system testing, EDFA system testing, transmittance and drift testing, which are essential for in-field and factory applications. The AE8600 offers exceptional stability and reliability, high-speed spectral sweeping, and multiple ways to export and analyze measurement data. It’s the ideal instrument for fast and precise optical spectral testing to satisfy long-term investment with the best cost performance value.
Specifications.

Optical Spectrum Measurement.
Wavelength range: 600 to 1700nm.
Wavelength resolution bandwidth: 0.02 to 2nm.
Wavelength resolution setting: 0.02nm, 0.06nm, 0.1nm, 0.2nm, 0.5nm, 1nm, 2nm.
Wavelength accuracy;
  1520 to 1620 nm ±0.02 nm,
  1450 to 1520 nm ±0.04 nm,
  Entire wavelength range ±0.1 nm.
Wavelength repeatability: ±0.005 nm (1 minute).
Wavelength linearity;
  ±0.01 nm (1520 to 1580 nm),
  ±0.02 nm (1450 to 1520 nm, 1580 to 1620 nm).
Minimum sampling resolution: 0.001nm.
Applicable fiber: SM(9.5/125μm), MMF(50/125μm, 62.5/125μm).

Optical Power Measurement.
Level sensitivity;
  -90dBm (1300-1620nm, resolution ≥0.05nm),
  -85dbm (1000-1300nm, resolution ≥0.05nm),
  -60dBm (600 - 1000nm, resolution ≥0.05nm).
Maximum input power: +20dBm.
Level accuracy: ±0.4dB (1310/1550nm, input level -20dBm).
Level linearity: ±0.05dB( input level: -50 to +10dBm).
Wavelength sampling points (Maximum): 50,000.
Optical return loss: >35dB (with angled-PC connector).
Polarization dependence: ±0.05dB (1550nm).
Dynamic range;
  Peak ±0.1nm 39dB (Resolution: 0.02nm),
  Peak ±0.4nm 60dB (Resolution: 0.05nm).