The Deviser Optical Spectrum Analyzer is a Monochromatic (Grating Filter) type OSA designed to cover O,C and L optical communication bands as well as visible light starting at 600nM.  (600 ~ 1700nm).    Specification are comparable to the latest model in the Yokogawa AQ6370 series at a price that fits your budget.  Some measurement types this OSA can easily accommodate are: Optical Amplifier (EDFA) Measurement, Fabry-Perot Laser Diode (FP LD) Analysis, Distributed Feedback Laser Diode (DFB LD) Analysis, Gas measurement, Wavelength-Division Multiplexing (WDM) Channel Analysis and Notch Width Measurement.
Original
Replacement
  
JDSU OSA-150 1250 to 1650 nm Optical Spectrum Analyzer (OSA) Module

DEVISER AE8600 600 to 1700 nm Optical Spectrum Analyzer

JDSU OSA-150   Description / Specification: DEVISER AE8600   Description / Specification:      
The JDSU OSA-150 is a Full-band, high-performance 1250 to 1650 nm Optical Spectrum Analyzer for testing optical systems and components. A new monochromator design provides ultra high optical resolution, and outstanding wavelength accuracy in a small and rugged OSA module, offering the best field solution for testing DWDM and CWDM networks during installation, maintenance and troubleshooting. The OSA-150 is JDSU's basic OSA with an optical resolution of 100 pm to measure CWDM and DWDM networks with moderate channel spacing of 100 GHz to CWDM. Specifications. Operating modes: WDM, Drift. Wavelength range: 1250 to 1650 nm. Measurement samples: 120,000. Number of optical channels: 256. Wavelength calibration: internal, online. Wavelength accuracy: ± 100 pm. Readout resolution: 1 pm. Resolution bandwidth (FWHM): 100 pm. Power measurement ranges; Dynamic range: -60 to +15 dBm. Absolute accuracy: typ. + 0.6 dB. Total safe power: +23 dBm. Readout resolution: 0.01 dB. Scanning time (full band): <5 s. Scanning time (C-band): <1 s. Optical rejection ratio (ORR) at ± 25 GHz (± 0.2 nm): not specfied. Optical rejection ratio (ORR) at ± 50 GHz (± 0.4 nm): typ. 40 dBc. Optical rejection ratio (ORR) at ± 50 GHz (± 0.4 nm): >43 dBc.


The Deviser E8600 is a high-precision diffraction-grating, high-resolution optical spectrometer with wavelength range of 600 nm to 1700 nm. The 10.1” LCD touchscreen and concise graphical user interface of AE8600 offer the easiest way to handle optical spectrum analysis. It provides a wide selection of test methodology, including laser spectrum scans (DPB, FP), WDM system testing, EDFA system testing, transmittance and drift testing, which are essential for in-field and factory applications. The AE8600 offers exceptional stability and reliability, high-speed spectral sweeping, and multiple ways to export and analyze measurement data. It’s the ideal instrument for fast and precise optical spectral testing to satisfy long-term investment with the best cost performance value.
Specifications.

Optical Spectrum Measurement.
Wavelength range: 600 to 1700nm.
Wavelength resolution bandwidth: 0.02 to 2nm.
Wavelength resolution setting: 0.02nm, 0.06nm, 0.1nm, 0.2nm, 0.5nm, 1nm, 2nm.
Wavelength accuracy;
  1520 to 1620 nm ±0.02 nm,
  1450 to 1520 nm ±0.04 nm,
  Entire wavelength range ±0.1 nm.
Wavelength repeatability: ±0.005 nm (1 minute).
Wavelength linearity;
  ±0.01 nm (1520 to 1580 nm),
  ±0.02 nm (1450 to 1520 nm, 1580 to 1620 nm).
Minimum sampling resolution: 0.001nm.
Applicable fiber: SM(9.5/125μm), MMF(50/125μm, 62.5/125μm).

Optical Power Measurement.
Level sensitivity;
  -90dBm (1300-1620nm, resolution ≥0.05nm),
  -85dbm (1000-1300nm, resolution ≥0.05nm),
  -60dBm (600 - 1000nm, resolution ≥0.05nm).
Maximum input power: +20dBm.
Level accuracy: ±0.4dB (1310/1550nm, input level -20dBm).
Level linearity: ±0.05dB( input level: -50 to +10dBm).
Wavelength sampling points (Maximum): 50,000.
Optical return loss: >35dB (with angled-PC connector).
Polarization dependence: ±0.05dB (1550nm).
Dynamic range;
  Peak ±0.1nm 39dB (Resolution: 0.02nm),
  Peak ±0.4nm 60dB (Resolution: 0.05nm).