The Ando AQ6317B is an optical spectrum analyzer that permits measuring the spectrums of light sources such as LD and LED and also the loss wavelength characteristics and transmission characteristics of optical fiber cables, optical filters, etc. It's measurable wavelength range is as wide as 600 to 1750 nm. This permits optical spectrum analysis of the near infra-red ray area. The equipment is provided with not only the basic performance of high resolution, high-sensitivity, highaccuracy, wide dynamic range and excellent linearity but also many functions such as three-dimensional display, various data processing function and program measuring function. As data output functions, the equipment is capable of hard-copying screens through a built-in high-speed printer, and reading/writing waveforms and programs through a built-in floppy disk. Besides this, the equipment is equipped with GP-IB as the standard configuration, thereby exerting full remote control. The AQ6317B is an improvement on the AQ6317 with features such as a 0.5 minute measurement time (as opposed to a full minute for the AQ6317).
|
|
The Deviser E8600 is a high-precision diffraction-grating, high-resolution optical spectrometer with wavelength range of 600 nm to 1700 nm. The 10.1” LCD touchscreen and concise graphical user interface of AE8600 offer the easiest way to handle optical spectrum analysis. It provides a wide selection of test methodology, including laser spectrum scans (DPB, FP), WDM system testing, EDFA system testing, transmittance and drift testing, which are essential for in-field and factory applications. The AE8600 offers exceptional stability and reliability, high-speed spectral sweeping, and multiple ways to export and analyze measurement data. It’s the ideal instrument for fast and precise optical spectral testing to satisfy long-term investment with the best cost performance value. Specifications.
Optical Spectrum Measurement. Wavelength range: 600 to 1700nm. Wavelength resolution bandwidth: 0.02 to 2nm. Wavelength resolution setting: 0.02nm, 0.06nm, 0.1nm, 0.2nm, 0.5nm, 1nm, 2nm. Wavelength accuracy; 1520 to 1620 nm ±0.02 nm, 1450 to 1520 nm ±0.04 nm, Entire wavelength range ±0.1 nm. Wavelength repeatability: ±0.005 nm (1 minute). Wavelength linearity; ±0.01 nm (1520 to 1580 nm), ±0.02 nm (1450 to 1520 nm, 1580 to 1620 nm). Minimum sampling resolution: 0.001nm. Applicable fiber: SM(9.5/125μm), MMF(50/125μm, 62.5/125μm).
Optical Power Measurement. Level sensitivity; -90dBm (1300-1620nm, resolution ≥0.05nm), -85dbm (1000-1300nm, resolution ≥0.05nm), -60dBm (600 - 1000nm, resolution ≥0.05nm). Maximum input power: +20dBm. Level accuracy: ±0.4dB (1310/1550nm, input level -20dBm). Level linearity: ±0.05dB( input level: -50 to +10dBm). Wavelength sampling points (Maximum): 50,000. Optical return loss: >35dB (with angled-PC connector). Polarization dependence: ±0.05dB (1550nm). Dynamic range; Peak ±0.1nm 39dB (Resolution: 0.02nm), Peak ±0.4nm 60dB (Resolution: 0.05nm).
|