|
|
General description of the
used AGILENT N9010A
for sale.
The Agilent N9010A EXA X-Series Signal Analyzer includes a list-sweep mode that lets you quickly perform power measurements at discrete frequency points. The fast sweep capability (1.5 seconds for a 26.5-GHz full-span sweep with 20 kHz RBW), available on the EXA with select option, saves significant amount of test time in your spurious response measurements. For devices that require multiple measurement applications, 30-ms mode switching helps you reduce overall test time. The Agilent N9010A delivers power meter-class level accuracy with ± 0.27 dB absolute amplitude accuracy. The EXA also makes it easy to characterize spurious response with typical displayed average noise level (DANL) of -163 dBm at 2 GHz and -156 dBm at 26.5 GHz. Excellent third-order intercept (TOI) performance (+19 dBm for the millimeter-wave models or +18 dBm for the RF/microwave models) helps to achieve the dynamic range demanded for accurately measuring the smallest signals in presence of the larger signal. To ensure accurate verification of, for example, oscillator performance, get typical phase noise specifications of -106 dBc/Hz with the millimeter-wave models or -105 dBc/Hz with the RF/microwave models (10-kHz offset from a 1-GHz carrier). Specifications.
Frequency ranges: 10 Hz to 3.6, 7.0, 13.6, or 26.5 GHz (option specific). Analysis bandwidth: 25 MHz (standard), 40 MHz (optional). Displayed average noise level (DANL): -163 dBm at 1 GHz, -156 dBm at 26.5 GHz preamplifier on. Third-order intermodulation (TOI) distortion: +18 dBm at 1 GHz. W-CDMA ACLR dynamic range: 68 dBc (73 dBc with noise correction on). Phase noise: -105 dBc/Hz (10 kHz offset, 1 GHz carrier). Amplitude accuracy: ± 0.27 dB (95th percentile to 3.6 GHz).
Options. N9010A-503 Frequency range, 10 Hz to 3.6 GHz. N9010A-507 Frequency range, 10 Hz to 7 GHz. N9010A-513 Frequency range, 10 Hz to 13.6 GHz. N9010A-526 Frequency range, 10 Hz to 26.5 GHz. N9010A-532 Frequency range, 10 Hz to 32 GHz. N9010A-544 Frequency range, 10 Hz to 44 GHz. N9010A-B25 Analysis bandwidth, 25 MHz. N9010A-B40 Analysis bandwidth, 40 MHz. N9010A-CR3 Connector, Wideband IF output. N9010A-CRP Connector, programmable rear IF output. N9010A-DP2 Digital Processor, 2 GB Capture Memory. N9010A-DVR DVD-ROM/CD-R/RW Drive. N9010A-EA3 Electronic attenuator, 3.6GHz. N9010A-EDP Enhanced display package. N9010A-EMC Basic EMC Functionality. N9010A-ESC External source control. N9010A-EXM External Mixing. N9010A-FSA Fine resolution step attenuator. N9010A-MLP Minimum loss pad, 50 to 75 ohm. N9010A-MPB Microwave preselector bypass. N9010A-P03 Preamplifier, 3.6 GHz. N9010A-P07 Preamplifier, 7 GHz. N9010A-P13 Preamplifier, 13.6 GHz. N9010A-P26 Preamplifier, 26.5 GHz. N9010A-PC4 Dual core high performance processor, 8GB RAM, removable SSD.
|
Purchase | Inventory ID | Serial Number | Instrument Notes | Sale Price |
| 137500 | MY55150120 | Options 513, FSA, EA3, MPB, DP2, FP2, P13, B25, B40, N9073A, N9080B | Price $38,000.00 |
|