Keysight (Agilent) 8481A REPAIR and Keysight (Agilent) 8481A CALIBRATION

The Keysight (Agilent) 8481A is currently in stock and available for purchase on our  Sales Page
It is also available for immediate rental.
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 8481A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8481A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Power Sensor?
Shop for Comparable Products on our
 used RF Power Sensor page

 
   Keysight (Agilent) 8481A   Description / Specification:    
Keysight (Agilent) 8481A 18 GHz Thermocouple Power Sensor

The HP 8481A 50-ohm silicon monolithic thermocouple Power Sensor gives you extremely low SWR even at mm-wave frequencies. Low SWR translates into minimum mismatch uncertainty and optimum measurement accuracy. The Agilent 8481A power sensor is designed for use with the E4418A/B, E4419A/B, 435B, 436A, 437B, 438A, 70100A and E1416A power meters. Frequency range: 10 MHz to 18 GHz. Maximum SWR: 10 to 30 MHz; 1.40, 30 to 50 MHz; 1.18, 50 MHz to 2 GHz; 1.10, 2 to 12.4 GHz; 1.18, 12.4 to 18 GHz; 1.28. Power of range: 0.3 microW to 100 mW(-30 to +20 dBm). Maximum power: 300 mW average, 15 W peak, 30W - us per pulse. Power Linearity: +10 to +20 dBm + 2, - 4%. Connector type: Type-N(m).



 

Standard Calibration $270.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8481A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

White Noise
White noise is noise whose power spectral density (watts/hertz) is constant for the frequency range of interest.


Please contact us for your Keysight (Agilent) 8481A REPAIR and/or Keysight (Agilent) 8481A 18 GHz Thermocouple Power Sensor CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: