Custom-Cal has a high success rate in the repair of the Keysight (Agilent) E3620A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E3620A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   Keysight (Agilent) E3620A   Description / Specification:    
Keysight (Agilent) E3620A Dual Output DC Power Supply

The Agilent E3620A Dual Output DC Power Supply has 0.01% load and line regulation which keeps the outputs steady with changes of the power line and load. The low normal-mode noise specification of 350 µV rms assures clean power for precision circuitry, and the low common-mode current specification of 1 µA rms minimizes line frequency current injection. It has separate digital panel meters to monitor both the voltage and current of any output simultaneously. An LED indicator for each output lets the user know when any supply is overloaded. All the outputs are protected against overload and short-circuit damage. Protection circuits prevent output voltage overshoot when supply is turned on and off. It provides two separate, independent and isolated power supplies in one small package. Each output has a ten-turn potentiometer for fine adjustment. Convenient meter selection allows the user to read voltage and current of either output. Each output can deliver up to 25 watts. Specifications. Number of output ranges: 1. Output ratings: Output 1; 0 to 25 V, 0 to 1 A. Output 2; 0 to 25 V, 0 to 1 A. Power (max.): 50W. Load and line regulation: 0.01% +2 mV. Ripple and noise: rms 350 µV, peak-to-peak 1.5 mV. Control mode: CV/CL. Resolution: Voltage 10 mV (0-20V), Current 1 mA (100 mA >20 V).



 

Standard Calibration $115.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E3620A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your Keysight (Agilent) E3620A REPAIR and/or Keysight (Agilent) E3620A Dual Output DC Power Supply CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: