Keysight (Agilent) 11792A CALIBRATION and Keysight (Agilent) 11792A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 11792A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Power Sensor?
Shop for Comparable Products on our
 used RF Power Sensor page

 
   Keysight (Agilent) 11792A   Description / Specification:    
Keysight (Agilent) 11792A 26.5 Sensor Module

The HP 11792A Sensor Module the system delivers the accuracy and resolution of a high performance power meter to 26.5 G Hz from +30 dBm to -100 dBm. It accurately measures AM, FM, and phaseM (including residuals and incidentals).
Specifications.
RF Power.
Range: +30 dBm (1W) to -20 dBm (10 μW).
Frequency range: 50 MHz to 26.5 GHz.
Linearity: ±0.02 dB (within range) ±0.02 dB per range change from reference range ± 1 digit.
Input SWR:
<1.10, f ≤2 .0 GHz.
<1.28, 2.0 GHz <1.40, 18.0 GHz
RF Frequency.
Range: 150 kHz to 26.5 GHz.
Maximum resolution: 10 Hz.



 

Standard Calibration $460.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 11792A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Modulation
Modulation is the coding of information onto the carrier frequency. This includes amplitude, frequency, or phase modulation techniques.

Sensitivity
Sensitivity is the smallest signal that can reliably detected. Sensitivity specifies the strength of the smallest signal at the input that causes the output signal power to be M times the output noise power where M must be specified. M=1 is very popular


Please contact us for your Keysight (Agilent) 11792A CALIBRATION and/or Keysight (Agilent) 11792A 26.5 Sensor Module REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: