Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 11896A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 11896A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Polarization Meter?
Shop for Comparable Products on our
 used Polarization Meter page or new Polarization Meter page

 
   Keysight (Agilent) 11896A   Description / Specification:    
Keysight (Agilent) 11896A Lightwave Polarization Controller

The HP 11896A Polarization Controller adjusts polarization and not power. Its optical fiber loop design provides all states of polarization with extremely small optical insertion-loss variations (±0.002 dB) over a wide spectral range (1250 to 1600 nm). This performance combination maximizes measurement accuracy for power-sensitive applications like polarization-dependent loss and gain. This is because the measurement uncertainty contributed by the polarization controller is minimized. Specifications. Operating Wavelength Range: 1250 to 1600 nm. Overall Insertion Loss: <2.0dB. Insertion Loss Variation (with adjustment/rotation): < ± .002 dB (Option 025). Polarization Extinction Ratio: > 40 dB. Polarization Adjustment Resolution: 0.18° (180° /1000 encoder positions). Angular Adjustment Accuracy: Minimum step size, ±0.18°; Greater than minimum step size, ±0.18°. Optical Port Return Loss: > 35 dB. Option 025: One meter fiber extender with FC/PC connector interfaces.



Looking for a replacement? Try the  UC INSTRUMENTS GM8015

Standard Calibration $635.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 11896A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bit Error Ratio (BER)
Bit Error Ratio (BER) is the ratio of errors caused by the number of bits in a data stream that have been altered due to noise, interference, distoriton or bit synchronization errors.

Flatness
Variation of insertion loss on the passband of an optical device.

Polarization Dependent Loss (PDL)
Polarization Dependent Loss is the difference between the maximum and minimum values of loss due to the variation of the polarization states of light propagating through a device. PDL is expressed in decibels. Calculated by; PDL = 10 log10 (Ep/Es), where EP and ES are the measured diffraction efficiencies for P- and S-plane polarized incident light, respectively.

Return Loss (RL)
Return Loss (RL) is the ratio of the incident power to the reflected power expressed in dB. RL = 10log (Pin/Pback)

Wavelength Resolution
Wavelength Resolution is the smallest possible displayed wavelength increment/decrement.


Please contact us for your Keysight (Agilent) 11896A REPAIR and/or Keysight (Agilent) 11896A Lightwave Polarization Controller CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: