Keysight (Agilent) E4402B REPAIR and Keysight (Agilent) E4402B CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) E4402B. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E4402B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Spectrum Analyzer?
Shop for Comparable Products on our
 used RF Spectrum Analyzer page or new RF Spectrum Analyzer page

 
   Keysight (Agilent) E4402B   Description / Specification:    
Keysight (Agilent) E4402B 3.0 GHz ESA-E Spectrum Analyzer

The Agilent E4402B ESA-E series general purpose, portable spectrum analyzer features; Segmented sweep saves measurement and setup time by viewing, in one sweep, only the frequency spans of interest. Paste together up to 32 discontinuous frequency or zero spans in one sweep. Eliminate the need for sweeping through unwanted frequencies and for multiple setups. Variable sweep (trace) points, ranging from 101 to 8192 points, optimize measurements for frequency resolution and accuracy versus speed. 16.8 cm, high-resolution color display with wide viewing angle make it easy to identify signals of interest. Split screen display shows wide spans while zooming in on signals of interest. The next generation user interface improves ease-of-use. Built-in help gives immediate assistance without manuals. One-button measurements such as ACP, Occupied BW, Emissions BW, channel power, 10 peaks table and harmonic distortion provide faster and more repeatable results. Multiple limit lines with margins and pass/fail messages simplify production testing. Built-in frequency counter with 1 Hz resolution precisely measures individual signals. Specifications. Frequency Range: 9 kHz to 3.0 GHz. Frequency Span Range: 0 Hz (zero span), 100 Hz to the range of the spectrum analyzer. Frequency Span Resolution 2 Hz x N^4. Frequency Sweep Time: 1 ms to 4000 s, Span = 0 Hz 10 µs to 4000 s. Resolution Bandwidth (RBW): 1 kHz to 5 MHz (–3 dB) in 1-3-10 sequence, 9 kHz and 120 kHz (-6 dB) EMI bandwidths. Amplitude Measurement Range: Displayed average noise level to maximum safe input level. Options; 1AX RS-232 and Parallel printer interface (includes RS-232 cable and BenchLink XL software) 1D5 High stability time base. 1D6 Time-gated spectrum analysis. 1D7 50 O/75 Omatching pad with dc block. 1DN 3 GHz tracking generator. 1DR Narrow resolution bandwidths. 1DS 3.0 GHz Preamplifier. A4J IF, sweep and video ports. AYX Fast zero-span sweeps. B72 Increases useable memory to 10 MB. BAA FM Demodulation/Deviation.



 

Standard Calibration $675.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E4402B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Adjacent Channel Power
Adjacent Channel Power is the power from a modulated communications channel that leaks into an adjacent channel. This leakage is usually specified as a ratio to the power in the main channel, but is sometimes an absolute power.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.


Please contact us for your Keysight (Agilent) E4402B REPAIR and/or Keysight (Agilent) E4402B 3.0 GHz ESA-E Spectrum Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: