Keysight (Agilent) 8563EC REPAIR and Keysight (Agilent) 8563EC CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 8563EC. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8563EC Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Spectrum Analyzer?
Shop for Comparable Products on our
 used RF Spectrum Analyzer page or new RF Spectrum Analyzer page

 
   Keysight (Agilent) 8563EC   Description / Specification:   Spec Sheet 
Keysight (Agilent) 8563EC 26.5 GHz Microwave Spectrum Analyzer

9 kHz to 26.5 GHz; 30 Hz to 26.5 GHz (Opt. 006), Portable Spectrum Analyzer. Frequency accuracy: ± 1.2 kHz (CF = 10 GHz). Frequency Span Range: 0 Hz, 100 Hz to maximum frequency. Frequency Readout Accuracy Span >2 MHz x N: ± (freq. readout x freq. ref. accuracy +5% x span +15% x RBW +10 Hz). Frequency Readout Accuracy Span ?2 MHz x N: ± (freq. readout x freq. ref. accuracy +1% x span +15% x RBW +10 Hz). Sweep Time Range: Span = 0 Hz: 50 ?s to 6,000 s; Span ?100 Hz: 50 ms to 100 ks. Resolution bandwidth range: 30 Hz to 3 MHz. Resolution bandwidth Accuracy: 1 Hz to 300 kHz: ±10%; 1 MHz: ±25%; 2 MHz: +50%, -25%. Video Bandwidth Range: 1 Hz to 3 MHz in a 1, 3, 10 sequence. Amplitude Range: Displayed average noise level to +30 dBm. Average noise level (narrowest RBW): -117 dBm. Optimum dynamic range 2nd/3rd order: 103 dB / 81 dB. Amplitude accuracy: ± 2.7dB



 

Standard Calibration $675.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8563EC. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.


Please contact us for your Keysight (Agilent) 8563EC REPAIR and/or Keysight (Agilent) 8563EC 26.5 GHz Microwave Spectrum Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*