Keysight (Agilent) 53149A CALIBRATION and Keysight (Agilent) 53149A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 53149A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another General Meter?
Shop for Comparable Products on our
 used General Meter page

 
   Keysight (Agilent) 53149A   Description / Specification:    
Keysight (Agilent) 53149A 46 GHz Counter/Power Meter/DVM

The Agilent 53149A 46 GHz microwave counter/power meter/dvms has all the fundamental measurements required to install and maintain digital microwave radio links. Rugged field portability and a battery option complete the ensemble. This instrument is also at home in ATE applications with GPIB and RS-232 fully programmable I/O ports as standard features. Specifications. Frequency Range Input 1 (1 M-ohm): 10 Hz to 125 MHz. Frequency Range Input 2 (50 ohm): 0.05 - 46 GHz. Damage Level Input 1: 5 Vrms to 120 Vp. Damage Level Input 2: +27 dBm. Channel 1 Resolution: Selectable 1 Hz to 1 MHz. Channel 1 Low Pass Filter: 50 kHz, selectable. Channel 2 Resolution: Selectable 1 Hz to 1 MHz. Channel 2 Acquisition Time: 100 ms to 140 ms. Channel 2 Gate Time: 1/Resolution. Power Meter Specifications; Frequency Range: 10 MHz to 50 GHz, sensor-dependent. Power Range: –70 dBm to +20 dBm, sensor-dependent. Power Sensors: 8480 series. DVM Specifications; Function: DC volts. Range: ±50 Vdc. Display: Backlit LCD. Options. Opt 001 Oven Timebase. Opt 002 Battery/DC Input.



 

Standard Calibration $600.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 53149A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your Keysight (Agilent) 53149A CALIBRATION and/or Keysight (Agilent) 53149A 46 GHz Counter/Power Meter/DVM REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: