Keysight (Agilent) 81652A REPAIR and Keysight (Agilent) 81652A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 81652A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 81652A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Laser Source (DFB-LD-WDM-BBS)?
Shop for Comparable Products on our
 used Laser Source (DFB-LD-WDM-BBS) page or new Laser Source (DFB-LD-WDM-BBS) page

 
   Keysight (Agilent) 81652A   Description / Specification:    
Keysight (Agilent) 81652A 1550/1625 nm Fabry Perot Laser Source Module

Standard Source Module (Fabry-Perot Laser). Center Wavelength: 1550 nm/1625 nm ±15 nm. Output Power: >0 dBm. Short term (15 min) CW power stability: <±0.005 dB typically <±0.003 dB with coherence control active. Long term (24 hr) CW power stability: typically <±0.03 dB. For use with Agilent 8163A/B Lightwave Multimeter, Agilent 8164A/B Lightwave Measurement System, and Agilent 8166A/B Lightwave Multichannel System.



 

Standard Calibration $350.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 81652A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bit Error Ratio (BER)
Bit Error Ratio (BER) is the ratio of errors caused by the number of bits in a data stream that have been altered due to noise, interference, distoriton or bit synchronization errors.

Flatness
Variation of insertion loss on the passband of an optical device.

Polarization Dependent Loss (PDL)
Polarization Dependent Loss is the difference between the maximum and minimum values of loss due to the variation of the polarization states of light propagating through a device. PDL is expressed in decibels. Calculated by; PDL = 10 log10 (Ep/Es), where EP and ES are the measured diffraction efficiencies for P- and S-plane polarized incident light, respectively.

Return Loss (RL)
Return Loss (RL) is the ratio of the incident power to the reflected power expressed in dB. RL = 10log (Pin/Pback)

Wavelength Resolution
Wavelength Resolution is the smallest possible displayed wavelength increment/decrement.


Please contact us for your Keysight (Agilent) 81652A REPAIR and/or Keysight (Agilent) 81652A 1550/1625 nm Fabry Perot Laser Source Module CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: