Keysight (Agilent) E5071B REPAIR and Keysight (Agilent) E5071B CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) E5071B. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E5071B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   Keysight (Agilent) E5071B   Description / Specification:   Spec Sheet 
Keysight (Agilent) E5071B 8.5 GHz ENA RF Network Analyzer

The Agilent E5071B 300 kHz to 8.5 GHz ENA RF Network Analyzer dramatically improves measurement accuracy and responds to current and future test needs. Because it performs up to 125 dB2 wide dynamic range at 10 Hz IFBW, the sweep speed can be faster at the required dynamic range. The trace noise is lowered to 0.001 dB rms at 3 kHz IFBW. It delivers accurate pass band ripple measurement of a filter. The Agilent E5071B offers integrated 2, 3, or 4 test ports, and enable various component measurements from 2-port filters to multiport devices like duplexers and couplers. The ENA offers built-in balanced measurements, matching circuit simulation, and port characteristic impedance conversion. In addition, the ENA provides frequency-offset and harmonics measurement capabilities. Specifications. Test Frequency range: 300 kHz to 8.5 GHz. Max port output power: -50 to 10 dBm. Test set: S-parameter test set. Number of test ports: 2, 3 or 4. IFBW: 10 Hz to 100 kHz (1, 1.5, 2, 3, 4, 5, 7 step). Number of points: 2 to 20,001. System dynamic range: 122 dB at 10 Hz BW (1.5 GHz to 3 GHz). Trace noise (magnitude): 0.001 dBrms at 3 kHz BW (3 MHz to 3 GHz). Display Size: 10.4 in TFT color LCD. Options. -008, Frequency-offset mode. -010, Time domain analysis capability. -790, Measurement wizard assistant software. -214, Two-port S-parameter test set. -314, Three-port S-parameter test set. -414, Four-port S-parameter test set. -016, Touch screen color LCD. -1E5, High stability frequency reference.



 

Standard Calibration $905.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E5071B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your Keysight (Agilent) E5071B REPAIR and/or Keysight (Agilent) E5071B 8.5 GHz ENA RF Network Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: