Keysight (Agilent) E8363B CALIBRATION and Keysight (Agilent) E8363B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E8363B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   Keysight (Agilent) E8363B   Description / Specification:    
Keysight (Agilent) E8363B 40 GHz PNA Microwave Network Analyzer

The Agilent E8363B 40 GHz PNA Series microwave vector network analyzer offers an unsurpassed combination of speed and precision to meet the challenges of general-purpose, high-performance and millimeterwave component testing from 10 MHz to 110 GHz. Frequency-offset capability for the PNA Series microwave network analyzer offers industry-leading accuracy and ease-of-use for non-linear measurements, including mixer and converter test, as well as amplifier IMD and harmonic measurement capability. Features. Frequency: 10 MHz to 40 GHz. 2 Ports, 4 measurement receivers. 110 dB dynamic range and <0.006 dB trace noise. <26 usec/point measurement speed, 32 channels, 16,001 points. TRL/LRM calibration, on-wafer, in-fixture, waveguide, and antenna measurements. Mixer conversion loss, return loss, isolation, and absolute group delay. Amplifier gain compression, harmonic, IMD, and pulsed-RF. Options. 014, Configurable test set. UNL, Extended power range and bias-tees. 016, Add receiver attenuators. 080, Frequency offset. 081, Reference receiver switch. 083, Frequency-converter measurement application. H11, IF access (for antenna and pulsed-RF measurements). H08, Pulsed-RF measurement capability. 010, Time-domain capability. 550, 4-port measurement application.



 

Standard Calibration $835.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E8363B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Adjacent Channel Power
Adjacent Channel Power is the power from a modulated communications channel that leaks into an adjacent channel. This leakage is usually specified as a ratio to the power in the main channel, but is sometimes an absolute power.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.


Please contact us for your Keysight (Agilent) E8363B CALIBRATION and/or Keysight (Agilent) E8363B 40 GHz PNA Microwave Network Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: