Keysight (Agilent) E8802A CALIBRATION and Keysight (Agilent) E8802A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E8802A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   Keysight (Agilent) E8802A   Description / Specification:    
Keysight (Agilent) E8802A 6 GHz S-parameter Vector Network Analyzer

The Agilent E8802A 6 GHz PNA RF Network Analyzer, provides TRL/LRM calibration for accurate characterization of in-fixture and on-wafer devices. It is ready to tackle components such as circulators, duplexers, splitters, couplers and base station combiner/divider units (CDUs) with their fast, simultaneous measurements of all three paths. For local storage, use the analyzer’s internal hard disk drive or connect a compatible CD drive. In addition, using drive mapping and the LAN interface, you can save data directly to remote PCs or file servers. This arrangement makes it very easy to develop statistical-process-controlled manufacturing environments. The Agilent E8802A allows a number of ways to connect and control other test equipment such as power meters or signal sources. You can choose to connect them via the available USB, GPIB, LAN, serial, or parallel interfaces. When utilizing any one of your Windows-supported automation. Specifications. Frequency Range: 300 kHz to 6 GHz. Number of Ports: 2. Measurement Receivers: 3. Dynamic Range (at test port): 125 dB @ 300 kHz to 1 MHz, 128 dB @ 1 MHz to 3 GHz, 118 dB @ 3 GHz to 6 GHz. Dynamic Range (receiver access): 140 dB @ 300 kHz to 1 MHz, 143 dB @ 1 MHz to 3 GHz, 133 dB @ 3 GHz to 6 GHz. Trace Noise (1 kHz IF BW) 300 kHz to 6 GHz: <0.002 dB, <0.010 deg rms. Maximum Output Power: +10 dBm @ 300 kHz to 6 GHz. Options. 014, Configurable test set. 1E1, Extended power range. 1E5, Add high stability timebase. 010, Time domain capability.



 

Standard Calibration $785.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E8802A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Modulation
Modulation is the coding of information onto the carrier frequency. This includes amplitude, frequency, or phase modulation techniques.

Sensitivity
Sensitivity is the smallest signal that can reliably detected. Sensitivity specifies the strength of the smallest signal at the input that causes the output signal power to be M times the output noise power where M must be specified. M=1 is very popular


Please contact us for your Keysight (Agilent) E8802A CALIBRATION and/or Keysight (Agilent) E8802A 6 GHz S-parameter Vector Network Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: