Keysight (Agilent) DSO5034A REPAIR and Keysight (Agilent) DSO5034A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) DSO5034A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) DSO5034A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) DSO5034A   Description / Specification:    
Keysight (Agilent) DSO5034A 4 Ch 300 MHz InfiniiVision Oscilloscope

The Agilent DSO5034A 300 MHz InfiniiVision oscilloscope offers responsive deep memory, fast update rates with minimal “dead time,” analog-like display systems, and integrated serial analysis. If you are characterizing signal jitter, a fast update rate gives you accurate results sooner. And when the fast update rate is combined with the 5000 Series’ XGA high-definition display (1024 x 768, 256 intensity levels), subtle differences in these acquisitions become obvious. The Agilent DSO5034A offers up to 12 bits of vertical resolution in real-time, single-shot mode. Analysis functions include subtract, multiply, integrate, and differentiate, as well as Fast Fourier Transforms (FFT). Specifications. Bandwidth: 300 MHz. Maximum sample rate: 2 GSa/s. Channels: 2 Ch 1, 2, 3, and 4 simultaneous acquisition. Memory: Up to 8 Mpts. Vertical resolution: 8 bits, up to 12 in high-resolution or averaging modes. Peak detection: 500 ps peak detect. Averaging: Selectable from 2, 4, 8, 16, 32, 64 ... to 65536. Calculated rise time (= 0.35/bandwidth): 1.17 ns. Range: 2 mV/div to 5 V/div (1 Mohm or 50 ohm). Input impedance: 1 Mohm ± 1% || 12 pF or 50 ohm ± 1.0%, selectable. Horizontal Range: 2 nsec/div to 50 sec/div. Resolution: 2.5 psec. Trigger Sources: Ch 1, 2, 3, 4, line, ext. Display: 6.3-inch (161 mm) diagonal color TFT LCD. Option 080, 8 Mpts memory upgrade (from base 1 Mpts).



 

Standard Calibration $460.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) DSO5034A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your Keysight (Agilent) DSO5034A REPAIR and/or Keysight (Agilent) DSO5034A 4 Ch 300 MHz InfiniiVision Oscilloscope CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: