Keysight (Agilent) E8244A CALIBRATION and Keysight (Agilent) E8244A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E8244A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   Keysight (Agilent) E8244A   Description / Specification:   Spec Sheet 
Keysight (Agilent) E8244A 40 GHz PSG-L CW Signal Generator

The Agilent E8244A PSG-L 40 GHz CW Signal Generator offers accurate characterization of products and eliminates the need of an external amplifier for testing high power devices. The E8244A provides 14 dBm at 40 GHz (option 1EA) reducing overall equipment and test costs. The superior level accuracy of the E8244A (+/- 0.7 dB) reduces test uncertainties and improves production throughput. Standard products have phase noise performance of -85 dBc/Hz at 1khz offset and -110 dBc/Hz at 20 kHz offset and a 10 GHz carrier. The E8244A provides improved performance with option UNJ of -98 dBc/Hz at 1 kHz offset and -110 dBc/Hz at 10 kHz offset and a 10 GHz carrier. Specifications. Frequency Range: 250 kHz to 40 GHz. Frequency Resolution: 0.01 Hz. Frequency Accuracy: Calibration = aging rate ± temperature effects ± line voltage effects. Switching speed (typical) Analog modulation: < 15 ms. Phase offset: Adjustable in nominal 0.1° increments. Internal timebase reference oscillator Aging rate: < ±1 x 10–7/year or < ±4.5 x 10–9/day after 45 days. External reference frequency: 1, 2, 2.5, 5, 10 MHz (within 1 ppm). Reference output Frequency: 10 MHz. Reference output Amplitude: > +4 dBm typical into 50 ohm load. Output Power: –20 to +9 dBm (250 kHz to 40 GHz). Interfaces: GPIB (IEEE-488.2,1987) with listen and talk, RS-232, and 10-base T-LAN interface. Options. -1E1, Adds output step attenuator for extended range to –135 dBm. -1EA, High RF output power +20 dBm at 20 GHz, +14 dBm at 40 GHz. -UNJ, Improved close-in phase noise.



 

Standard Calibration $890.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E8244A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a component, link or network will operate.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Ringing
Ringing is an unwanted oscillation of a voltage or current.


Please contact us for your Keysight (Agilent) E8244A CALIBRATION and/or Keysight (Agilent) E8244A 40 GHz PSG-L CW Signal Generator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: