Keysight (Agilent) 86060B REPAIR and Keysight (Agilent) 86060B CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 86060B. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 86060B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Optical Switch?
Shop for Comparable Products on our
 used Optical Switch page

 
   Keysight (Agilent) 86060B   Description / Specification:    
Keysight (Agilent) 86060B Compact Lightwave Switch

Compact Lightwave Switch. Insertion Loss: Single-mode Switches, 2.0 dB (1.0 dB); Multi-mode Switches, 1.5 dB (1.0 dB). Repeatability: Sequential Switching ± 0.02dB (±0.01 dB). Isolation: -80 dB(-100 dB). Number of Input Channels: Option 001 Single input channel, Option 002 Two input channels. Wavelength and Fiber Type: Option109 1280 -1650 nm, 9/125 µm single-mode fiber; Option 162 1280 -1650 nm, 62.5/125 µm multimode fiber; Option H63 700 -900 nm, 62.5/125 µm multimode fiber; Option H50 1280 -1650 nm, 50/125 µm multimode fiber (special order): Option H51 830 -1350 nm, 50/125 µm multimode fiber (special order). Port Type: Option 050 Connectors on front panel (with Option 204 only); Option 051 Connectors on rear panel (for connectorized outputs only); Option 052 1 meter fiber out the rear panel (for connectorized outputs, connector is at the end of the 1 meter fiber). Output Channels: 4, 6, 8



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 86060B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Absolute Wavelength Accuracy
Absolute Wavelength Accuracy is the maximum difference between the actual wavelength and the displayed wavelength of the Optical Source. Wavelength is defined as wavelength in vacuum.

Decibel (dB)
A unit of measurement of optical power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Nanometer (nm)
A unit of measure used to measure wavelength of light, meaning one one-billionth of a meter

Relative Intensity Noise (RIN)
Relative intensity noise (RIN), describes the instability in the power level of a laser. The noise term is important to describe lasers used in fiber-optic communication and LIDAR remote sensing. It is the square of the (spectrally resolved) RMS optical power amplitude divided by the measurement bandwidth and the square of the average optical power, expressed in dB/Hz.

Total Return loss
In an optical fiber, the loss that takes place at any discontinuity of refractive index, especially at an air-glass interface such as a fiber endface, at which a fraction of the optical signal is reflected back toward the source. RL = - 10log10 (Preflected/Preference)


Please contact us for your Keysight (Agilent) 86060B REPAIR and/or Keysight (Agilent) 86060B Compact Lightwave Switch CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: