Keysight (Agilent) N4373A REPAIR and Keysight (Agilent) N4373A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) N4373A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) N4373A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Lightwave Measurement System?
Shop for Comparable Products on our
 used Lightwave Measurement System page or new Lightwave Measurement System page

 
   Keysight (Agilent) N4373A   Description / Specification:    
Keysight (Agilent) N4373A Lightwave Component Analyzer

Lightwave Component Analyzer, S-Parameter analysis (linear transmission / reflection analysis). System bandwidth: (opt 300) 300 kHz to 3 GHz ENA, (opt 301) 300 kHz to 8.5 GHz ENA, (opt 302) 300 kHz to 20 GHz PNA-L 2 port, (opt 303) 300 kHz to 20 GHz PNA-L 4 port. Wavelength: (opt 100) 1310 nm Wavelength (only with N4373A-200, 201 or 202), (opt 101) 1550 nm Wavelength (only with N4373A-200 or 201 or 202), (opt 102) 1310 & 1550 nm Wavelength (only with N4373A-200 or 201 or 202). Frequency: (opt 200) 3 GHz Frequency single-mode fiber, (opt 201) 8.5 GHz Frequency single-mode fiber, (opt 202) 20 GHz Frequency single-mode fiber. Optical Input Wavelength range: 800 nm to 1650 nm. LAN, USB and GPIB instrument control and data interfaces.



 

Standard Calibration $2,635.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) N4373A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Coherence Length
Average distance over which superimposed waves lose their phase relationships

Linewidth
Linewidth is the width of a spectral line in terms of wavelength, wave number and frequency.

Power Flatness Versus Wavelength
When changing the wavelength at constant power setting and recording the differences between actual and displayed power levels, the power flatness is ± half the span (in dB) between the maximum and the minimum of the measured power levels.

Spectral Width
Spectral Width is the wavelength interval over which the magnitude of all spectral components is equal to or greater than a specified fraction of the magnitude of the component having the maximum value. In optical communications applications, the usual method of specifying spectral width is the full width at half maximum. This is the same convention used in bandwidth, defined as the frequency range where power drops by less than half (at most -3 dB).

Telecom Bands
Optical fiber communications typically operate in a wavelength region corresponding to one of the following Bands. O Band (original): 1260–1360 nm. E Band (extended): 1360–1460 nm. S Band (short wavelengths): 1460–1530 nm. C Band (conventional): 1530–1565 nm. L Band (long wavelengths): 1565–1625 nm. U Band (ultralong wavelengths): 1625–1675 nm


Please contact us for your Keysight (Agilent) N4373A REPAIR and/or Keysight (Agilent) N4373A Lightwave Component Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: